Installation
IMPORTANT: Before installation read all the
instructions and make sure that the voltage (V)
and the frequency (Hz) indicated on the rating
plate are exactly the same as the voltage and
frequency in your home. The rating plate can be
found behind the grease filters.
The manufacturer declines all responsibility in the event of the installer
failing to observe all the accident prevention regulations in force,
which are necessary for normal use and the regular operation of the
electric system.
Electrical connection
YOUR COOKER HOOD IS INTENDED FOR FITTED AND
PERMANENT INSTALLATION.
o
If not supplied the power cable must be connected to the
terminals marked L (live) and N (neutral) in the hood and fixed
with a cable clamp.
o
The cooker hood’s power cable must be fitted upstream from the
electrical connection, using an omni-polar switch with a contact
distance of at least 3 mm.
WARNING: THIS APPLIANCE MUST NOT BE
EARTHED.
It should only be connected by a competent
person, using fixed wiring via a double pole switched fused
spur outlet
OR
connected using a 13 AMP plug with a 3
AMP fuse fitted.
15