o
IMPORTANT:
They must be screwed clockwise into position and
not just slotted into the holes on each corner. If there are
brackets provided, then you must screw the legs through them.
Gas connection
This appliance must be installed by a competent
person in accordance with the current versions of
the following UK (United Kingdom) or ROI (Republic
of Ireland) Regulations and Safety Standards or
their European Norm Replacements.
Important information
o
This cooker is supplied to run on
natural gas only
and cannot
be used on any other type of gas without modification.
o
Conversion for use on LPG and other gases must only be
undertaken by a qualified person. For information on the use of
other gases, please contact the Baumatic Technical Department.
o
The cooker must be installed by a qualified person, in
accordance with the current edition of the Gas Safety
(Installation and Use) (Amendment) Regulations and the
relevant building/I.E.E. Regulations.
o
Failure to install the appliance correctly could invalidate
Baumatic’s guarantee and lead to prosecution under the
regulations quoted above.
o
In the UK,
CORGI
registered installers are authorised to
undertake the installation and service work, in compliance with
the above regulations.
Ventilation requirements
o
The room containing the cooker should have an air supply in
accordance with the current edition of BS 5440: Part 2:
o
The room must have opening windows or equivalent; some
rooms may also require a permanent vent.
o
If the room has a volume between 5 and 10m³, it will require an
air vent of 50cm² (effective area). Unless it has a door which
opens directly to the outside.
o
If the room has a volume of less than 5m³, it will require an air
vent of 100cm² (effective area).
26