o
Remove the cover on the rear of the oven to access the terminal
block.
o
Open the mains terminal block cover as shown, unscrew the
cable clamp and unscrew (not fully) the screws in the mains
terminal block which will secure the three wires of the mains
cable.
o
1, 2 and 3 are the live connection, 4 and 5 are the neutral
connection and the remaining one is the earth connection.
o
The live wire MUST be placed in connection number 1.
The neutral wire MUST be placed in connection number 4.
The earth wire MUST be placed in the connection marked with
the symbol.
o
The brass links must be positioned as marked in the above
diagram and once established ALL terminal screws must be
tightened down firmly.
o
Fit the cable and refit the cable clamp
o
If when the oven is first switched on, it does not operate
correctly, you should recheck that the terminal screws are
all fully tightened between the links. This should be done
before contacting the Baumatic Service Department.
o
Allow sufficient cable length for the cooker to be pulled out for
cleaning, but do not let it hang closer than 50 mm to the floor.
o
The cable can be looped if necessary, but make sure that is not
kinked or trapped when the cooker is in position.
o
The cable can be looped if necessary, but make sure that is not
kinked or trapped when the oven is in position. Care must be
taken to avoid the cable being in contact with hot parts of the
appliance (i.e. areas that will get hotter than 75
°
C).
44