22
INSTALLATION
The installation must be carried out by a suitably
qualified person, in accordance with the current
version of the following.
o
UK Regulations and Safety Standards or their European
Norm Replacements.
o
Building Regulations (issued by the Department of the
Environment).
o
Building Standards (issued by the Scottish Development
Department).
o
IEE Wiring Regulations.
o
Electricity At Work Regulations.
Before connecting the appliance, make sure that the supply voltage
marked on the rating plate corresponds with your mains supply
voltage.
WARNING: THIS APPLIANCE MUST BE EARTHED.
o
This appliance should be wired into a 15A double pole switched
fused spur outlet, having 3 mm contact separation and placed in
an easily accessible position adjacent to the appliance. The spur
outlet must still be accessible even when your oven is located in
its housing.
o
To connect the oven power cord, loosen and remove the cover
on the terminal block, in order to gain access to the contacts
inside. Make the connection, securing the cord in place with the
cable clamp provided and then immediately close the terminal
block cover again.
o
If you have to change the oven power cord, the earthing
(yellow/green) conductor must always be 10 mm longer than the
line conductors.
o
Care must be taken to ensure that the temperature of the mains
supply cable does not exceed 50°C.
o
If the mains supply cable is damaged, then it must be replaced
by an appropriate replacement which can be obtained from the
Baumatic Spares Department.