Electrical connection
This appliance must be installed by a qualified
person in accordance with the latest edition of the
I.E.E. Regulations and in compliance with Baumatic’s
instructions.
Before connecting the appliance, make sure that the supply voltage
marked on the rating plate corresponds with your mains supply
voltage.
WARNING: THIS APPLIANCE MUST BE EARTHED.
o
This appliance must be wired into a 40A double pole switched
fused spur outlet, having 3 mm contact separation and placed in
an easily accessible position adjacent to the appliance. It should
not be located above the appliance and no more than 1.25m
away from it.
o
The spur outlet must still be accessible even when your hob is
located in its operating position.
o
Cable type: H05 V2V2 – F3 x 2.5², or F4 x 2.5 mm²
Connecting the mains supply cable
o
The mains terminal block is located on the underside of the hob
and the terminals are accessible by removing the terminal block
cover by removing the cover screw. IMPORTANT: The power
cable is not supplied with the appliance.