28
Replacing the mains supply cable
If the mains supply cable is damaged, then it must be replaced by an
appropriate replacement.
The mains supply cable should be replaced in accordance with the
following instructions:
o
Switch the appliance off at the control switch.
o
Open the terminal block on the underside of the hob.
o
Unscrew the terminal screws fixing the cable.
o
Replace the cable with one of the same length and specification.
o
The “green-yellow” earth wire must be connected to the terminal
marked
. It must be about 10 mm longer than the live and
neutral wires.
o
The “blue” neutral wire must be connected to the terminal
marked with letter the (N) - the live wire must be connected to
the terminal marked with the letter (L).