o
Reassemble all the burners carefully; in particular you should
make sure that the flame spreader is correctly placed on the
burner.
IMPORTANT: After changing the injectors YOU MUST follow the
minimum flow adjustment section below.
OPERATING
PRESSURE GAS
RATE
DIAMETER
INJECTOR
HEAT
INPUT
BY-PASS
BURNERS
GAS MBAR g/h L/h
1/100 mm
MIN MAX
1/100
mm
LPG -
Butane
28-30 218
88
800
3000
LPG -
Propane
37 214
88
800
3000
Rapid
Natural 20
286
117-Y 800
3000
44
LPG -
Butane
28-30 131
68
600
1800
LPG -
Propane
37 129
68
600
1800
Semi-rapid
Natural 20
171
98-Z 600
1800
34
LPG -
Butane
28-30 73
51
400 1000
LPG -
Propane
37 71
51
400
1000
Auxiliary
Natural 20
95 75-X 400
1000
28
LPG -
Butane
28-30 276
98
1600
3800
LPG -
Propane
37 272
98
1600
3800
Ultra-rapid
Natural 20
362
135-K 1600
3800
62
LPG-
Butane
28-30 284
94
1000
3900
LPG -
Propane
37 279
94
1000
3900
Oven
Natural 20
371
142 1000
3900
52
Minimum flow adjustment for hob gas taps.
All work must be carried out by a GASSAFE
registered engineer.
o
Light the burner and set the knob at the
minimum position.
o
Remove the knob from the tap. The
adjustment screw is located beside the valve
body.
34