![Baumatic BC190.2SS Insrtuction Manual Download Page 31](http://html1.mh-extra.com/html/baumatic/bc190-2ss/bc190-2ss_insrtuction-manual_2709601031.webp)
o
If the cooker has been converted for use with LPG, then it should
be connected to the gas supply using an appropriate bayonet
type hose. The hose MUST be suitable for use with LPG gas,
these are identifiable by a red band or stripe.
o
A hose length of 0.9m to 1.25m is recommended. The length of
hose chosen should be such that when the cooker is in situ, the
hose does not touch the floor.
o
Care should be taken to ensure that the temperature rise of
areas at the rear of the cooker that are likely to come in contact
with the flexible hose do not exceed 70°C.
o
Gas pressure may be checked on a semi-rapid hob burner.
Remove the appropriate injector and attach a test nipple. Light
the other burners and observe that the gas pressure complies
with the gas standards in force.
Gas adjustment (Conversion to LPG for the hob top)
All work must be carried out by a CORGI registered
engineer.
IMPORTANT: Always isolate the cooker from the electricity
supply before changing the injectors and/or adjusting the
minimum flow of the burners.
o
Remove the pan-stands,
burners and flame spreaders.