background image

INSTALLATION INSTRUCTIONS 

ELECTRICAL CONNECTION 

 

Before connecting the appliance, make sure the supply voltage marked on the rating Plate 
corresponds with the mains supply voltage. 

 

WARNING – THIS APPLIANCE MUST BE EARTHED 

 
This appliance should be wired into a double pole Switched Fused Spur Outlet having 3 mm 
contact separation and the fuse rating reduced to 3 Amps. 
 

IMPORTANT

 

The wires in the main supply lead are coloured in accordance with the following code:- 
Green and Yellow 

–   Earth 

Blue – 

Neutral 

Brown – 

Live 

 
The connections must be made as follows:- 
The wire coloured Green and Yellow must be connected to the terminal marked ‘E’ or the earth 
symbol (

) or coloured green and yellow. 

The wire coloured Blue must be connected to the terminal marked ‘N’ or coloured blue or Black. 
The wire coloured Brown must be connected to the terminal marked ‘L’ or coloured brown or 
red. 
NOTE: The terminals marked ‘SUPPLY’ are for the mains supply wires and the terminations 
marked ‘LOAD’ are for the appliance wires. 
 
The electrical outlet is to be positioned in an easily accessible position adjacent to the appliance. 
In the event that it is necessary to replace the mains supply lead, the replacement must conform to 
the specification listed in the Technical Data. Ensure that the colour code connection is correct 
and that all screws are tightened correctly. 
 

 

11 

Summary of Contents for AS4.1

Page 1: ...GAS HOBS USER AND INSTALLATION INSTRUCTIONS...

Page 2: ...r future reference please record the following information which can be found on the Rating Plate and the date of purchase which can be found in the invoice Model Number Serial Number Date of Purchase...

Page 3: ...NTS General Information page 4 Warning and Safety Instructions page 5 Instructions for Use pages 6 7 Instructions for Installation Pages 8 12 Technical Data Pages 12 13 Conditions of Guarantee Back co...

Page 4: ...agreement of Baumatic Ltd would invalidate any warrantee or liability claim Your new appliance is guaranteed against electrical or mechanical defects subject to certain exclusions noted in Baumatic Lt...

Page 5: ...t size for the heating area to be used never smaller Do not allow electrical fittings or cables to be in contact with hot areas of the appliance Do not use the appliance for space heating or to dry cl...

Page 6: ...an be released 2 Manual Ignition After pressing in and turning the appropriate knob anti clockwise to the large flame symbol press the ignition button located on the control panel The ignition spark w...

Page 7: ...l burners are variable between full and low positions WARNING Do not use commercial simmering aids as these can create excessive heat which can damage the appliance CLEANING THE APPLIANCE Always allow...

Page 8: ...tallation of Flues and Ventilation for Gas Appliances Baumatic Ltd Installation Instructions POSITIONING THE APPLIANCE This appliance is classified as Class 3 and therefore is to be built into a kitch...

Page 9: ...t leave a gap in the sealing agent or overlap the thickness NOTE do not use any Silicone based sealant as this can damage the worktop surface if repairs are required 4 Insert the appliance into the ap...

Page 10: ...for LPG proceed as follows Isolate the appliance from the electricity and gas supplies Remove the pan supports and burner assemblies Replace the injectors with the alternative type supplied Use the a...

Page 11: ...Green and Yellow must be connected to the terminal marked E or the earth symbol or coloured green and yellow The wire coloured Blue must be connected to the terminal marked N or coloured blue or Blac...

Page 12: ...h high temperature grease reassemble into position and rotate a few times Remove the cone again and remove any excess grease making sure that the gas ducts are not obstructed with grease Carefully rea...

Page 13: ...3 0 0 7 1 75 0 4 1 0 0 35 7 5 AS5 1 3 0 0 7 1 75 0 4 1 0 0 35 10 5 B70 3 0 0 7 1 75 0 4 1 0 0 35 7 5 JET SIZING CONVERSION TABLE NATURAL GAS LPG Model Large Medium Small Wok Fish NG LPG NG LPG NG LPG...

Page 14: ...ranty period This guarantee applies to UK mainland and Northern Ireland only THIS GUARANTEE DOES NOT COVER Any damage caused by transit misuse or neglect Cosmetic and perishable parts plugs fuses ligh...

Reviews: