Baumalight GXM350 Operator'S Manual Download Page 21

The stump grinder is equipped with a case drain 

connector. You must connect your case drain line 

and route to the excavator hydraulic reservoir. 

It is normal for a hydraulic motor to have a slight 

amount of internal leakage. 

The case drain line will allow this internal leakage to 

be returned to the reservoir, preventing excessive 

pressure on the motor seal. 

Starting with model year 2022, stump grinders 

will be equipped with a zero leak relief valve (A) 

installed in the case drain line. 

A

If the case drain line is not connected or becomes 

obstructed, the zero leak relief valve will vent the  

pressurized hydraulic fluid to the atmosphere. The 

zero leak relief valve will self reset after hydraulic 

pressure reduced.

A properly installed case drain protected by a zero 

leak relief valve will save the work of replacing the 

motor shaft seal and also improve the efficiency of 

your hydraulic system.

5�5 Zero Leak Case Drain Relief Valve

^

 

WARNING

Pressurized  fluids  can  penetrate  the 

skin�

Keep bystanders away from machine 

during operation� 

A tiny, almost invisible leak can penetrate 

the skin, thereby requiring immediate 

medical attention�

If hydraulic fluid is coming out of the zero leak relief 

valve, shut down machine immediately. Inspect 

the case drain line connection and lines. Contact 

your dealer if case drain lines and connection are  

good.

NOTICE

Environmental hazard�

Clean  up  any  spilled  hydraulic  fluid 

immediately�

19

Summary of Contents for GXM350

Page 1: ...GXM350 GXM550 And GXM750 Stump Grinder OPERATOR S MANUAL Issue Date March 2022...

Page 2: ...rds From Modifying Equipment 5 2 3 Maintenance Hazards 6 3 SAFETY SIGNS 8 4 OPERATION 10 4 1 Preparation For Use 10 4 2 Hydraulic Connections 10 4 3 Machine Components 12 4 4 Attach To Excavator 12 4...

Page 3: ...manual handy for frequent reference and to pass on to new operators or owners Call your Baumalight dealer distributor or the factory if you need assistance information or additional copies of the manu...

Page 4: ...voided could result in minor or moderate injury NOTICE NOTICE Indicates a situation that could result in damage to the equipment or other property 2 1 Safety Alert Symbol And Safety Words 2 2 Operatio...

Page 5: ...apply to you and your industry This manual is not to replace any regulations or laws Additional information may be found at www asae org or www osha gov If you do not understand any part of this manu...

Page 6: ...ore raising equipment Have local utilities locate and mark under ground wires cables pipelines and other hazards before grinding DO NOT leave the operator s seat if any part of the equipment contacts...

Page 7: ...t before applying pressure Search for leaks with a piece of cardboard or wood Protect hands and body from high pressure fluids If an accident occurs see a doctor immediately Any fluid injected into th...

Page 8: ...rocedure before servicing WARNING Crushing hazard Before performing inspections service or maintenance Park machine on firm level surface Engage excavator parking brake Turn engine off and remove key...

Page 9: ...7...

Page 10: ...dealer Dashes lines indicate items hidden from view unless cover is opened B E D C A B A D005262 WARNING P65 warning information WARNING This product can expose you to chemicals including 1 3 Butadien...

Page 11: ...hazard Keep away from machine D005126 D D005517 WARNING Remove key before servicing D005517 E D005125 WARNING Read and understand safety signs on the machine and operating instructions in this manual...

Page 12: ...he stump grinder before each start up Check for loose or missing parts and any damage that may have occurred during moving or shipping Review all excavator pre start instructions and ensure that all r...

Page 13: ...11...

Page 14: ...d follow all safety instructions 2 Attach excavator to stump grinder See excavator operator s manual 3 Verify pins are secure in the correct position 4 Connect hydraulic hoses Verify hydraulic hoses a...

Page 15: ...e 2 Lower stump grinder to the ground 3 Shut off engine and remove key 4 Disconnect hydraulic hoses 5 Detach excavator from stump grinder See excavator Operator s Manual WARNING Prevent death or serio...

Page 16: ...ferent from the excavator seat and can be very deceiving Operate all functions in an open area with excavator in idle to get a good feel for the controls do not expect to get first stump done fast Run...

Page 17: ...proved dust mask or respirator Follow local state and federal regulations 1 Attach stump grinder to excavator See Attaching Detaching in this section 2 If stump is on a grade position excavator in low...

Page 18: ...w P65Warnings ca gov wood WARNING Wear an approved dust mask or respirator Follow local state and federal regulations Each tooth can be rotated up to two times before replacement is necessary 1 Park e...

Page 19: ...or more information go to www P65Warnings ca gov wood WARNING Wear an approved dust mask or respirator Follow local state and federal regulations 1 Park excavator and grinder on a level surface 2 Lowe...

Page 20: ...rnia to cause cancer Avoid inhaling wood dust or use a dust mask or other safeguards for personal protection For more information go to www P65Warnings ca gov wood WARNING Wear an approved dust mask o...

Page 21: ...aulic fluid to the atmosphere The zero leak relief valve will self reset after hydraulic pressure reduced A properly installed case drain protected by a zero leak relief valve will save the work of re...

Page 22: ...nough oil flow Check flow control on excavator See your dealer Rotor does not have much power Low oil Check oil level in excavator Add if necessary Oil filter plugged Replace excavator oil filter Reli...

Page 23: ...nd including loss of profits The manufacturer is under no circumstances liable for carrier unit damage of any kind The manufacturer is not liable for the maintenance of the product This warranty is ex...

Page 24: ...4575 Powell Rd Wallenstein Ontario Canada N0B 2S0 Phone 519 698 9864 Toll Free 866 820 7603 Fax 519 698 1087 www baumalight com For parts specifications and the latest machine information please visit...

Reviews: