For technical questions, please call 1-888-866-5797.

Item 63433 

        

S

AFET

y

Op
ERA

TION

M

AINTENAN

c

E

S

ETU

p

Grounding

TO pREVENT ELEcTRIc SHOcK AND DEATH FROM 
INcORREcT GROUNDING WIRE cONNEcTION: 
check with a qualified electrician if you are in doubt as to whether the outlet is properly 
grounded.  Do not modify the power cord plug provided with the tool.  Never remove the 

grounding prong from the plug.  Do not use the tool if the power cord or plug is damaged.  If damaged, have 
it repaired by a service facility before use.  If the plug will not fit the outlet, have a proper outlet installed by 
a qualified electrician.

Grounded Tools: Tools with Three prong plugs

 

3-prong plug and Outlet

1.  Tools marked with “Grounding Required” have 

a three wire cord and three prong grounding 
plug.  The plug must be connected to a properly 
grounded outlet.  If the tool should electrically 
malfunction or break down, grounding provides 
a low resistance path to carry electricity away 
from the user, reducing the risk of electric shock.  

(See 3-prong plug and Outlet.)

2.  The grounding prong in the plug is connected 

through the green wire inside the cord to the 
grounding system in the tool.  The green wire 
in the cord must be the only wire connected to 
the tool’s grounding system and must never 
be attached to an electrically “live” terminal.  

(See 3-prong plug and Outlet.)

3.  The tool must be plugged into an appropriate outlet, 

properly installed and grounded in accordance 
with all codes and ordinances.  The plug and outlet 
should look like those in the preceding illustration.   

(See 3-prong plug and Outlet.)

Double Insulated Tools: Tools with Two prong plugs

 

Outlets for 2-prong plug

1.  Tools marked “Double Insulated” do not 

require grounding.  They have a special 
double insulation system which satisfies 
OSHA requirements and complies with 
the applicable standards of Underwriters 
Laboratories, Inc., the Canadian Standard 
Association, and the National Electrical Code.

2.  Double insulated tools may be used in either of the 

120 volt outlets shown in the preceding illustration.

   

(See Outlets for 2-prong plug.)

Summary of Contents for 1642E-B

Page 1: ...ce When unpacking make sure that the product is intact and undamaged If any parts are missing or broken please call 1 888 866 5797 as soon as possible Copyright 2016 by Harbor Freight Tools All rights...

Page 2: ...on which if not avoided could result in minor or moderate injury Addresses practices not related to personal injury IMpORTANT SAFETy INFORMATION General power Tool Safety Warnings Read all safety warn...

Page 3: ...he off position before connecting to power source picking up or carrying the tool DUU LQJ SRZHU WRROV ZLWK RXU ILQJHU RQ WKH 7ULJJHU RU HQHUJL LQJ SRZHU WRROV WKDW have the Trigger on invites accident...

Page 4: ...l it has come to a complete stop Moving parts can grab the surface and pull the tool out of your control 9 When using a handheld power tool maintain a firm grip on the tool with both hands to resist s...

Page 5: ...vibration when there is a choice 5 Include vibration free periods each day of work 6 Grip tool as lightly as possible while still keeping safe control of it Let the tool do the work 7 To reduce vibra...

Page 6: ...to carry electricity away from the user reducing the risk of electric shock See 3 prong plug and Outlet 2 The grounding prong in the plug is connected through the green wire inside the cord to the gro...

Page 7: ...to indicate it is acceptable for outdoor use 7 Make sure the extension cord is properly wired and in good electrical condition Always replace a damaged extension cord or have it repaired by a qualifie...

Page 8: ...Use Read the ENTIRE IMpORTANT SAFETy INFORMATION section at the beginning of this manual including all text under subheadings therein before set up or use of this product Note For additional informati...

Page 9: ...e Rotary Hammer The body of the Hammer will interfere with the Depth Gauge if the Handle is in the bottom position 2 Loosen the Lock Nut then slide the Depth Gauge through the Depth Gauge Slot on the...

Page 10: ...while working 3 Secure loose workpieces using a vise or clamps not included to prevent movement while working 4 There must not be objects such as utility lines nearby that will present a hazard while...

Page 11: ...section TO pREVENT SERIOUS INJURy FROM TOOL FAILURE Do not use damaged equipment If abnormal noise or vibration occurs have the problem corrected before further use cleaning Maintenance and Lubricatio...

Page 12: ...cord is needed use one with the proper diameter for its length and load See WHQVLRQ RUGV in Grounding section on page 6 Performance decreases over time 1 Carbon brushes worn or damaged 2 Bit dull or...

Page 13: ...IAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO...

Page 14: ...il Retaining Bearing 1 44 Middle Cover 1 1004 Intermediate Shaft Assembly 45 Split Washer 1 46 Bearing 607 2Z 2 47 Bearing Board 607 1 part Description Qty 48 Primary Gear 1 49 Needle Bearing K9x12x10...

Page 15: ...Page 15 For technical questions please call 1 888 866 5797 Item 63433 SAFETy OpERATION MAINTENANcE SETUp Assembly Diagram...

Page 16: ...the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPL...