7
SYMPTOM
PROBABLE CAUSE
CORRECTIVE ACTION
DISPLAY IS
INACCURATE
Meter operated below
minimum flow rate.
Increase flow rate.
Meter partially clogged with
debris.
Remove meter. Clean
carefully. Make sure rotor
spins freely and water supply
is free of debris.
Sealant material wrapped
around meter rotor.
If applicable, remove rotor.
Make sure rotor spins freely
and water supply is free of
debris. .
DISPLAY IS
FADED OR
BLANK
Batteries weak, dead, or not
connected.
Check and replace batteries.
Computer defective.
Contact the factory.
NORMAL FLOW
RATE BUT
DISPLAY DOES
NOT SHOW
COUNT
Rotor stuck or damaged.
Remove meter. Make sure
rotor spins freely.
Sealant material wrapped
around rotor.
Remove meter. Make sure
rotor spins freely.
Computer defective.
Contact the factory.
REDUCED FLOW
RATE AND
DISPLAY DOES
NOT SHOW
COUNT
Meter clogged with debris.
Remove meter. Clean
carefully. Make sure rotor
spins freely and water supply
is free of debris.
Below minimum flow rate.
Increase flow.
TROUBLESHOOTING
Summary of Contents for Direct Fill Link+
Page 1: ...English 1 11 Direct Fill Link Direct Fill Link with Bluetooth Enabled Flow Meter...
Page 13: ...12...
Page 14: ...13...
Page 15: ...14...