background image

BATTERY TENDER

 PLUS  

PRODUCT INFORMATION   

______________________________________________________________________________________ 
Deltran Corporation, 801 U.S. Hwy 92 East, DeLand, FL 32724

              

Page 

5

 

of

 

5

           

Phone 386-736-7900   FAX 386-736-0379    

www.batterytender.com

                     Revised April 4, 2002 

 
 

Battery Tender

®

 Plus 12V1.25A: 

 

Stage 1) Bulk Charge:

  Red Light On, Green Light Off, Constant Current = 1.25 Amps, 

Transition to Stage 2, Absorption Charge when battery voltage reaches 14.4 VDC. 

Stage 2) Absorption Charge: 

Red Light On, Absorption Voltage = 14.4 VDC Transition 

to Float Charge when battery charging current drops below 0.1 amp or until 6 to 8 hours 
have elapsed. 
Stage 3) There is no Equalization Charge, Go directly to stage 4. 

Stage 4) Float Charge:

  Red Light Off, Green Light On.  Float Voltage = 13.2 VDC.  If 

an external load is applied to the battery while the charger is in stage 4, Float Charge, and 
if the battery voltage drops below a range between 12.0 to 12.5 VDC, then the charge 
cycle restarts. 
 

14.4 Volts

Approximately

80% Recharged

Battery Tender     Plus Battery Charger

12 Vdc 1.25 Adc Output

Typical Charging Curve

Absorption

(6 to 8 Hours Max)

Charging Time (Hours)

14.0

100% Charge 12.9 Volts

    0% Charge 11.4 Volts

Bulk Charge

11.5

11.0

0

1

2

12.5

12.0

13.5

13.0

Open

Circuit

Voltage

Range

5

3

4

6

7

1.25 Amps

16.0

15.0

14.5

15.5

Battery

Terminal

Voltage

(VOLTS)

R

1.2

0.1 Amp

13.2 Volts

Float / Maintenance

13

8

9

10

11

12

16

14

15

0.1

0.2

0

0.6

0.4

1.0

0.8

100% 

Recharged

2.0

1.6

1.25

1.4

1.8

Battery

Charging

Current

(AMPS)

 

 

Figure 2

  Charging Graph:  Battery Tender

®

 Plus 12V1.25A

   

 

Reviews: