• The deviation (7) in mm/m of the
currently measured angle is displayed
when an angle < 5.7° (max. 100
mm/m
)
is measured.
• A small arrow icon (8) additionally
appears indicating if the device is
measuring ascends (arrow up) or
descends (arrow down).
CALIBRATION
The digital spirit level has been calibrated in
the factory for maximum accuracy. If
necessary, the digital spirit level can be re-
calibrated.
1. Switch off the digital spirit level. Place it
on a flat and level surface.
2. Press and hold the Hold/Light key (5).
Then additionally press the On/Off key
(3). The number “-
1
-“ is flashing on the
display.
3. Press the On/Off key (3) once more. The
number “-
2
-“ is flashing on the display.
4. Horizontally flip over the digital spirit level
by 180º. Then press the On/Off key (3)
one more time to finish the calibration
process.
Note:
Ensure the digital spirit level is kept
absolutely steady during calibration.
TECHNICAL DATA
Batteries:
2 x LR03 (AAA)
Battery life:
Approx. 100 hours
Measuring Range:
0º … +/-90°
Resolution:
0.1°
Measuring Accuracy: 0.2°
Dimensions:
416 x 50 x 21 mm
Weight (incl. Battery): Approx. 330 g
CLEANING AND STORING
• Clean the digital spirit level with a smooth
and dry linen cloth. If necessary moisten
it slightly.
• Do not use any solvents, detergents,
sharp edged objects and the like for
cleaning.
• Store the unit on a dry place that is
protected from dust and dirt.
• Store it out of reach of children.
DISPOSAL AND RECYCLING
Batteries and rechargeable batteries
do not belong in household garbage.
For battery disposal, please check
with your local council.
The tool is shipped in packaging to reduce
transport damage. This packaging is a raw
material and as such can either be reused
or can be fed back into the raw material
cycle. The tool and its accessories are
made from various materials such as metals
and plastics. Take defective components to
a special refuse collection point. Ask about
these at your specialist shop or local
council.
The product and the user manual may be
subject to changes. Technical data may be
changed without prior notice.
8
TM
7061251 Ma # 1207-30.indd 8
30-07-12 09:30