9/26/2018
Thyme Manual
https://bastl-instruments.github.io/thyme/manual.html#/Introduction
47/48
ID
Name
Description
Manual Check
Special
Failure
Indication
ID
Name
Description
Manual Check
Special
Failure
Indication
1
Knobs
Set all knobs together at a
set of positions (off, center,
full). Once all reach the
target position the test
proceeds to the next
position. The knob LEDs
indicate when a knob has
reached its target position.
Check if the knobs
reach the middle
position only when
they are set halfway to
assure they have the
correct curve
None
2
Knob LEDs
Knob LEDs fade in one after
another.
Smooth Fading
None
3
Buttons
Press button closest to the
LED that lights up. Pressing
the wrong button is an error.
None
LED closest
to button
that trigged
unexpectedly
is lit up.
4
EEPROM
All bytes of EEPROM are
written to, read back and
compared with expected
value. Original data is
preserved. Shows progress
bar.
None
None
5
External
Connect external testing
utility to test CV, analog
clock and footswitch. Set in
this order: CV to center - 5
Clock edges - CV to off - 5
Footswitch presses - CV to
full
Unit should not react
on its own
None
6
Bootloader
Tries to place lower board
into bootloader mode.
None
None
7
MIDI
Connect MIDI cable between
input and output. Devices
sends random data and
checks if it can receive it.
None