0–0.7 VDC

Indicates a logical 0 (with inverter disabled).

1.8–3.4 VDC Indicates a logical 1 (with inverter disabled).

Maximum input leakage current:

 10 

μ

A

Internal pull-up resistor:

 25 k

Ω

 typical, 7 to 41 k

Ω

.

To increase the voltage allowed on the I/O input lines, attach the optional 

dart I/O

board

 to the camera. The I/O board makes the camera compatible with TTL input

signals.

Operation as Output

Voltage

Description

3.4 VDC

Absolute maximum. This voltage must never be exceeded. Doing so
may damage the camera and voids the warranty.

0–0.5 VDC

Indicates a logical 0 (with inverter disabled).

2.4–3.3 VDC Indicates a logical 1 (with inverter disabled).

Maximum current allowed through the output circuit:

 2 mA

Circuit Diagrams

  See 

Circuit Diagrams for Basler dart Cameras

.

Cable Requirements

USB 3.0 Cable

Use a high-quality USB 3.0 cable with a USB 3.0 Micro-B plug.
Do 

not

 use cables with a USB 1.x/2.0 Micro-B cable plug, even if you are connecting

the camera to a USB 2.0 port. Otherwise, the camera may not work properly. 

To 

avoid EMI

, cables must be shielded, as speci ed in the USB 3.0 standard.

Basler recommends using USB 3.0 cables from the 

Basler Vision Components

range.

For more information, see the 

Recommended Accessories for Basler USB 3.0 Cameras

document.

Summary of Contents for daA1280-54um

Page 1: ...ations General Speci cations Spectral Response Mechanical Speci cations Camera Dimensions and Mounting Points Maximum Allowed Lens Intrusion Stress Test Results Requirements Environmental Requirements...

Page 2: ...sler dart S mount color cameras are not equipped with an IR cut lter If you want to operate a Basler dart S mount color camera with an IR cut lter you must attach a lens with an integrated IR cut lter...

Page 3: ...W x H S mount and CS mount models 20 mm x 29 mm x 29 mm Bare board model 7 2 mm x 27 mm x 27 mm Weight S mount and CS mount models 15 g Bare board model 5 g Conformity CE includes RoHS UL Listed GenIC...

Page 4: ...filter Camera acA2500 14gm t en 2Fdaa1280 54um htm 4 11 The spectral response curve excludes lens characteristics and light source characteristics Mechanical Speci cations Camera Dimensions and Mount...

Page 5: ...Maximum Allowed Lens Intrusion See Maximum Allowed Lens Intrusion Stress Test Results See Stress Test Results Requirements Environmental Requirements Temperature and Humidity Bare Board Variant S Moun...

Page 6: ...point i e at the camera front Heat Dissipation See Providing Heat Dissipation Electrical Requirements DANGER Electric Shock Hazard Unapproved power supplies may cause electric shock Serious injury or...

Page 7: ...o 2 kV contact discharge The tests were performed according to the EN61000 4 2 standard By default they are con gured as input lines Due to their high impedance inputs are susceptible to noise and ele...

Page 8: ...ing so may damage the camera and voids the warranty 0 0 5 VDC Indicates a logical 0 with inverter disabled 2 4 3 3 VDC Indicates a logical 1 with inverter disabled Maximum current allowed through the...

Page 9: ...ut time trigger delay jitter or the precision of the exposure time set If you operate a daA1280 54um uc camera on a USB 2 0 port image noise may increase This is because the image sensor of the camera...

Page 10: ...3 0 connection to supply power to the camera and to transmit video data and control signals Connection assignments and numbering adhere to the Universal Serial Bus 3 0 standard The recommended mating...

Page 11: ...ameras simultaneously Protects the dart camera against short circuits The board can be mounted on the back of the Basler dart circuit board The connectors of the I O board replace the standard I O con...

Reviews: