BE1-MMS100
FUNCTIONAL DESCRIPTION,
continued
Data Item
Va
Vb
Vc
Ia
lb
lc
In
kWa
kWb
kWc
kW
kWh Exp
kWh Imp
kWh Tot
kVARa
kVARb
kVARc
kVAR
kVARh Exp
kVARh Imp
kVARh Tot
kVAh Exp
kVAh Imp
kVAh Tot
Elapsed Time
PF
Freq
Ph A
Ph B
Ph C
Pulse Ch 1
Pulse Ch 2
Pulse Ch 3
Pulse Ch 4
Status Ch 1
Status Ch 2
Status Ch 3
Status Ch 4
Relay Out 1
Relay Out 2
Relay Out 3
Relay Out 4
Relay Out 5
Relay Out 6
THD% - a
THO% - b
THD% - c
fund - a
fund - b
fund - c
harm n a*
harm n b*
harm n c*
Data Description
Voltage Input A
Voltage Input B
C
Current Input A
Current Input B
Current Input C
Current Input Neutral
Kilowatts phase A pair inputs
Kilowatts phase B pair inputs
Kilowatts phase C pair inputs
Kilowatts for feed
Kilowatt hours - Exported
Kilowatt hours - Imported
Kilowatt hours - Accumulated
Kilovars phase A pair inputs
Kilovars phase B pair inputs
Kilovars phase C pair inputs
kvar for feed
kvarhours - Exported
kvarhours - Imported
kvarhours - Accumulated
kVAhours - Exported
kVAhours - Imported
kVAhours - Accumulated
Elapsed time since last RESET
Power Factor
Phase Angle A pair inputs
Phase Angle B pair inputs
Phase Angle C pair inputs
Pulse count on channel 1
Pulse count on channel 2
Pulse count on channel 3
Pulse count on channel 4
Status Input on Channel 1
Status Input on Channel 2
Status Input on Channel 3
Status Input on Channel 4
Output Relay Contacts Chan 1
Output Relay Contacts Chan 2
Output Relay Contacts Chan 3
Output Relay Contacts Chan 4
Output Relay Contacts Chan 5
Output Relay Contacts Chan 6
Total Harmonic Distortion Ph a
Total Harmonic Distortion Ph b
Total Harmonic Distortion Ph c
Phase A Fundamental
Phase B Fundamental
Phase C Fundamental
Phase A Harmonic n
Phase B Harmonic n
Phase C Harmonic n
Interval
1 sec
1 sec
1 sec
1 sec
1 sec
1 sec
1 sec
1 sec
1 sec
1 sec
1 sec
1 min
1 min
1 min
1 sec
1 sec
1 sec
1 sec
1 min
1 min
1 min
1 min
1 min
1 min
1 sec
1 sec
1 sec
1 sec
1 sec
1 sec
1 min
1 min
1 min
1 min
1 cycle
1 cycle
1 cycle
1 cycle
On Demand
On Demand
On Demand
On Demand
On Demand
On Demand
1 min
1 min
1 min
1 min
1 min
1 min
1 min
1 min
1 min
Note: History is limited to 18 days for the DNP 3.0 option.
*where n is a number corresponding to a harmonic from 2 to 31
8
Alarm
Display Historical
X
Yes
15 min
X
Yes
15 min
X
Yes
15 min
X
Yes
15 min
X
Yes
15 min
X
Yes
15 min
X
Yes
15 min
X
15 min
X
15 min
X
15 min
X
Yes
15 min
Yes
Total
Yes
Total
Yes
Total
X
15 min
X
15 min
X
15 min
X
Yes
15 min
Yes
Total
Yes
Total
Yes
Total
Yes
Total
Yes
Total
Yes
Total
Yes
Total
X
Yes
15 min
X
Yes
15 min
X
Yes
15 min
X
Yes
15 min
X
Yes
15 min
X
Yes
15 min
X
10 count MCD
X
10 count MCD
X
10 count MCD
X
1 0 count MCD
X
Yes
X
Yes
X
Yes
Min
Max Day
X
X
36
X
X
36
X
X
36
X
X
36
X
X
36
X
X
36
X
X
36
X
X
36
X
X
36
X
X
36
X
X
36
X
X
X
X
X
X
X
X
36
X
X
36
X
X
36
X
X
36
X
X
X
X
X
X
X
X
X
X
X
X
X
X
36
36
36
36
36
36
www
. ElectricalPartManuals
. com