Configuring the Camera
4-26
Basler A400k
DRAFT
Field Name:
Max
Offset:
0x0005
Size:
2 Bytes
Type:
Read only
Description:
Maximum allowed integer value for the starting column setting. This field is updated to re-
flect limitations caused by the way any related features are set.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the max value
Byte 2 = Mid byte of the max value
Field Name:
Increment
Offset:
0x0007
Size:
2 Bytes
Type:
Read only
Description:
An integer value indicating the increment for the starting column setting.
The 2 bytes in this field are interpreted as follows:
Byte 1 = Low byte of the max value
Byte 2 = Mid byte of the max value