Configuring the Camera
Basler A400k
4-9
DRAFT
Camera Status Inquiry
The camera has been programmed to detect several error conditions. When an error condition is
detected, a flag is set. The camera status inquiry register lets you read the error flags.
Register Base Address:
0x0C00
Field Name:
Register Status
Offset:
0x0000
Size:
1 Byte
Type:
Read only
Description:
The integer value in this field indicates the status of this inquiry register:
0x00 = The register is not available.
0x01 = The register is available.
Field Name:
Camera Status
Offset:
0x0001
Size:
4 Bytes
Type:
Read only
Description:
Each bit in this field specifies an error condition (see table below). Bit 0 is the least signifi-
cant bit. If a bit is set to 1, the error condition assigned to that bit is present. If the bit is set
to 0, the error is not present.
Bit
Description
0
The camera is unlocked.
1
The camera is booting or is busy performing an internal operation (such as
generating shading values).
2
A reset has occurred. This bit is auto-cleared on read.
3
Parameter error, for example, a parameter has been set to a value that is out
of range or not allowed or in conflict with other settings.
4
A user set load has failed.
5
A file operation has failed.
6
Reserved
7
A binary read/write command protocol error has been detected. For more in-
formation about the error, read the Binary Command Protocol Status Inquiry
register (see page
). This bit clears when you read the Binary Command
Protocol Status Inquiry register.
8 ... 15
Reserved
16
An FPGA not ready error has occurred. For more information about the error,
read the FPGA Status Inquiry registers (see pages
and
). This bit
clears when you read the FPGA Status Inquiry registers.
17
A trigger error has occurred. Either the frame rate has been exceeded or the
ExSync signal is missing. For more information about the error, read the
FPGA Status Inquiry registers (see pages
and
). This bit clears
when you read the FPGA Status Inquiry registers.
18
Reserved
19
The last column FPN shading value generation process failed.
The column FPN shading value generation process can fail if the pixel val-
ues in the frames captured during the generation process are too high. (The
process should be performed in darkness or in very low light conditions.)
This bit will clear when you perform a successful shading value generation
procedure.
20 ... 31
Reserved
Summary of Contents for A400K
Page 1: ...Basler A400k USER S MANUAL Document Number DA00062410 Release Date 27 September 2007 ...
Page 4: ......
Page 25: ...Camera Interface Basler A400k 2 9 DRAFT Figure 2 5 A402k Camera Frame Grabber Interface ...
Page 26: ...Camera Interface 2 10 Basler A400k DRAFT Figure 2 6 A403k Camera Frame Grabber Interface ...
Page 27: ...Camera Interface Basler A400k 2 11 DRAFT Figure 2 7 A404k Camera Frame Grabber Interface ...
Page 52: ...Camera Interface 2 36 Basler A400k DRAFT ...
Page 154: ...Configuring the Camera 4 54 Basler A400k DRAFT ...
Page 168: ...Troubleshooting 6 10 Basler A400k DRAFT ...
Page 172: ...Feedback iv Basler A400k DRAFT ...
Page 176: ...Index viii Basler A400k DRAFT ...