background image

Head Section

Assembly

999-0881-920SP

Head Section

Assembly

Seat Sections

(one on each side)

999-0881-004G

Knee Sections

(one on each side)

999-0881-912G

Foot Section Assembly

999-0881-930SP

1/2" long

Carriage Bolt

100-5231-002

5/16-18

Nylock Nut

100-6731-006

HEAD END

FOOT END

  DETAIL: Attachment,

  Seat Pan Section to

 Head and Knee

Sections

DETAIL:

Attachment,

Knee Section to

Foot Section

Foot Section

Assembly

SLEEP DECK SERVICE PARTS

1.  Listed below are the 

only

 Slide-W-I-D-E 

Adjustable Sleep Deck service parts:

•  (1) Head Section Assembly, complete 

(one per bed required);

•  (1) Foot Section Assembly, complete 

(one per bed required);

•  (2) Knee Section, universal side piece 

(two per bed required); and

•  (2) Seat Section, universal side piece 

(two per bed required)

2.  Head Section Assembly and Knee Sections 

must be installed before Seat Sections and 

Foot Section Assembly.

  Seat Sections and Foot Section Assembly 

must be disassembled before Head Section 

Assembly and Knee Sections.

3.  Carriage bolts and nylock nuts, oriented as 

shown below, can be disassembled and 

assembled using 

1

/

2

" deep socket or 

1

/

2

wrench.

GF Health Products, Inc. - www.grahamfield.com 

Slide-W-I-D-E Expandable/Retractable Sleep Deck Supplement 999-0881-190G

ZENITH SERIES

7

Summary of Contents for APS9867406

Page 1: ...the bed read this entire manual as well as all sections pertaining to your bed model in your bed s Primary Service Manual before use 42 39 35 35 39 42 ZZ98674 with pedal lock ZZ98774 84 Custom APS7867...

Page 2: ...dical Products 336 Trowbridge Drive Fond du Lac WI 54937 For Slide WIDE Expandable Retractable Sleep Deck service parts contact our Customer Service Department at 770 368 4700 Manufactured by GF Healt...

Page 3: ...y weight should be evenly distributed over the sleeping surface of the bed DO NOT allow the patient to lie sit or lean in such a way that their entire body weight is placed only on the raised head or...

Page 4: ...pulling out the pins by the small rings Each detent pin is attached to a lanyard which is connected to a screw on the underside of the deck to prevent misplacement see illustrations below 3 Stand at t...

Page 5: ...h rails 6 At the head end slide the mounting tube L portions into the main frame rail hollow ends a FOR 80 BED LENGTH Slide the mounting tubes in until the first tube holes align with the first rail h...

Page 6: ...TANT MATTRESS RETAINERS MUST MATCH HEADBOARD FOOTBOARD AND WALLSAVER POSITIONS SEE EACH BED MODEL S SERVICE MANUAL To attach the four Mattress Retainers insert Retainer ends into sleep deck corner hol...

Page 7: ...ts 1 Head Section Assembly complete one per bed required 1 Foot Section Assembly complete one per bed required 2 Knee Section universal side piece two per bed required and 2 Seat Section universal sid...

Page 8: ...ortheast Parkway Atlanta Georgia 30360 Customer Service phone 770 368 4700 fax 770 368 2386 2013 GF Health Products Inc All Rights Reserved Basic American Medical Products Zenith and Slide W I D E are...

Reviews: