background image

 
 

Program Levels 

7

 

 

 

 

 

 

 

 A PV around  

the lower limit  
of the bargraph 
programmed range 
does not visualize on it.

 

Programming order 

 

Set full access to device parameters. 

 

Adjust the parameters. 

 

If needed, restrict the access again  
by adjusting the 

Access Control Level

 parameter. 

Access control (Hidden level) 

 

Hold 

 

depressed while turning  

the power supply on and until 

QxL

 appears. 

 

Set access level according to Table 1.

 

Basic level 

At power-on, TI250 enters Basic level.  
At this level, the device shows on the display  
the measured input value (PV) with a resolution, 
according to the 

Point Position

 parameter,  

and on the bargraph – the relative position of PV 
within the programmed range of the bargraph.  

 

If the whole part of PV cannot be entirely 
displayed, the unit generates blinking 
'overflow' messages (

oL

 or 

-oL

, depending 

on PV sign). If PV is out of the bargraph 
programmed range, the corresponding  
endmost LED of the bargraph blinks. 

 

If PV is out of the device physical operating 
range, blinking symbolic messages – 

<_>

 (under-range) or 

{+}

 (over-range) – 

appear on the display, and the respective  
endmost LED of the bargraph blinks. 

 

Upon entering Basic level, 

BB

I250 may display 

the 

ini

 message, indicating that some time

is necessary for filter initialization.  
In such case, the bargraph goes off. 

 

The 

noi

 message may appear as a result 

of the peak filter operation (see '

Input filtration

'). 

In such case, the bargraph goes off. 

Set-point adjustment (Level L1) 

 

To enter 

Set Point 1 

adjustment mode, press 

and hold

 

 until 

%[1

 appears on the display. 

Release the key to view the set-point value. 

 

To enter 

Set Point 2 

adjustment mode,

 

follow 

the same procedure, but start with the 

 key. 

 

Summary of Contents for BBI250

Page 1: ...LSJ tel 46 40 88009 fax 46 40 929877 E mail sales basi se www basi se BBI250 OPERATION MANUAL Please read this Operation Manual before mounting and operating Save the Manual for future references PROG...

Page 2: ...provided when relay contacts are open Small AC current 1 5 mA at 230 VAC may still flow through the RC circuit All signal wires must be shielded They must not be packaged together with power cables Ne...

Page 3: ...ould be powered ONLY by external source Output wiring Connect the outputs with regard to their types see Specifications via the respective terminals Power supply wiring Connect the right power supply...

Page 4: ...l action direction of output K1 Differential 1 e1 Relay switching differential over set point for output K1 Differential 1 me1 Relay switching differential under set point for output K1 Time On 1 ym1...

Page 5: ...ath the pointer light together with it dot only the pointer lights coo hEA cooling activates over set point heating activates under set point 0 999 ISU less than high range limit Set Point 1 0 999 ISU...

Page 6: ...tively or Confirm the adjusted value by pressing simultaneously or If the new value has not been confirmed and no key has been pressed for a certain period of time value adjustment automatically cease...

Page 7: ...be entirely displayed the unit generates blinking overflow messages oL or oL depending on PV sign If PV is out of the bargraph programmed range the corresponding endmost LED of the bargraph blinks If...

Page 8: ...en pressed for a while the device automatically returns to Basic level storing all confirmed changes For quick exiting and saving use key combination or Output Control Alarm output operation The alarm...

Page 9: ...L h W11 W21 ym1 ym2 out of range W12 W22 y 1 y 2 out of range W13 W23 km1 km2 out of range W14 W24 k 1 k 2 out of range W15 W25 e1 e2 out of range W16 W26 me1 me2 out of range W17 W27 1 2 outside L h...

Page 10: ...a normal signal It is possible only if the input signal has not been changed with more than the Gradient value for 4 subsequent samples If the device has not determined a normal signal for 20 subseque...

Page 11: ...nts of Directives 2004 108 EC 2006 95 EC and 2011 65 EU Bengt Ste n CEO BASI Instrument AB Waste Disposal Do not dispose of electronic devices together with household waste material If disposed of wit...

Page 12: ...IP65 IP54 IP20 Warranty and Support serial number manufacturing date QC check mark passed stamp BASI Instrument AB P O Box 53 PSE 275 06 VOLLSJ SWEDEN tel 46 40 88009 fax 46 40 929877 E mail sales bas...

Reviews: