Parameter Programming 

6

 
 
 
 

 

-  Changing  

Point Position 

value

  

reflects on the real value 
of all parameters 
with ISU! 

E.g.: changing  

Point Position 

value 

from (0) to (0.0) 
would change 
a Set-point value 
of 100 to 10.0!!!

 

 

Setting numerical parameter value 

 

Enter parameter value adjustment mode 
(see '

Program Levels

').

 

 

The whole part of the value together with 
the left zeroes appears on the display,  
and the rightmost digit blinks.

 

 

To select another digit, press 

 

.

 

 

The 3 rightmost digits can accept values 
from 

0

 to

 

9

, and the leftmost digit 

can also accept the values 

-

 and

 

`

.

 

 

To increase or decrease the blinking digit  
value, use respectively 

 or 

 

.

 

 

Confirm the adjusted value by pressing 
simultaneously

 

 + 

 

or 

 + 

.

 

 

If the new value has not been confirmed  
and no key has been pressed for a certain 
period of time, value adjustment 
automatically ceases, and the parameter 
retains its initial value.

 

Setting symbolic parameter value 

 

In parameter value adjustment mode,  
use 

 or 

 to change the value,  

and to confirm, press 

 + 

 

or 

 + 

.

 

 

If the new value has not been confirmed  
and no key has been pressed for a certain 
period of time, value adjustment  
automatically ceases, and the parameter 
retains its initial value.

 

Setting color  

 

Enter 

Bargraph Color

 parameter value 

adjustment mode. 

 

Each of the bargraph LEDs lights in its 
designated color, and the lowermost blinks.

 

 

To select other LED, use 

.

 

 

To change the LED color, use 

 or 

.

 

 

To cease the adjustment, press 

 + 

  

or 

 + 

 or just wait awhile.

 

 

Summary of Contents for BBI250

Page 1: ...LSJ tel 46 40 88009 fax 46 40 929877 E mail sales basi se www basi se BBI250 OPERATION MANUAL Please read this Operation Manual before mounting and operating Save the Manual for future references PROG...

Page 2: ...provided when relay contacts are open Small AC current 1 5 mA at 230 VAC may still flow through the RC circuit All signal wires must be shielded They must not be packaged together with power cables Ne...

Page 3: ...ould be powered ONLY by external source Output wiring Connect the outputs with regard to their types see Specifications via the respective terminals Power supply wiring Connect the right power supply...

Page 4: ...l action direction of output K1 Differential 1 e1 Relay switching differential over set point for output K1 Differential 1 me1 Relay switching differential under set point for output K1 Time On 1 ym1...

Page 5: ...ath the pointer light together with it dot only the pointer lights coo hEA cooling activates over set point heating activates under set point 0 999 ISU less than high range limit Set Point 1 0 999 ISU...

Page 6: ...tively or Confirm the adjusted value by pressing simultaneously or If the new value has not been confirmed and no key has been pressed for a certain period of time value adjustment automatically cease...

Page 7: ...be entirely displayed the unit generates blinking overflow messages oL or oL depending on PV sign If PV is out of the bargraph programmed range the corresponding endmost LED of the bargraph blinks If...

Page 8: ...en pressed for a while the device automatically returns to Basic level storing all confirmed changes For quick exiting and saving use key combination or Output Control Alarm output operation The alarm...

Page 9: ...L h W11 W21 ym1 ym2 out of range W12 W22 y 1 y 2 out of range W13 W23 km1 km2 out of range W14 W24 k 1 k 2 out of range W15 W25 e1 e2 out of range W16 W26 me1 me2 out of range W17 W27 1 2 outside L h...

Page 10: ...a normal signal It is possible only if the input signal has not been changed with more than the Gradient value for 4 subsequent samples If the device has not determined a normal signal for 20 subseque...

Page 11: ...nts of Directives 2004 108 EC 2006 95 EC and 2011 65 EU Bengt Ste n CEO BASI Instrument AB Waste Disposal Do not dispose of electronic devices together with household waste material If disposed of wit...

Page 12: ...IP65 IP54 IP20 Warranty and Support serial number manufacturing date QC check mark passed stamp BASI Instrument AB P O Box 53 PSE 275 06 VOLLSJ SWEDEN tel 46 40 88009 fax 46 40 929877 E mail sales bas...

Reviews: