Installation         

Heed all information contained in the chapter “Preparing installation”.

•  Place the product on a soft, nonslip surface. The frosted glass must face upward.
•  Loosen the two flat-head screws and remove the cover.
•  Remove the frosted glass.
•  Use the base unit as a template and mark the positions of both drill holes on the installation 

surface through the two large screw holes.

When drilling or tightening screws, make sure not to damage any cables, wires or 

pipes located underneath the surface

•  Drill both holes in the wall and insert the screw anchors.
•  Guide the mains cable through the rubber seal.

Also use a suitable amount of sealing agent (i.e. Silicone) for additional sealing.

•  Fasten the base unit to the installation surface using the two fastening screws and two 

washers.

•  Slip the two silicone sleeves over the feeder.
•  Connect the feeder to the corresponding screw terminals:

 - Brown cable = L
 - Blue cable = N
 - Green/yellow cable = PE/ground wire, grounding symbol

The ground wire must be connected to the terminal block under all circumstances.
If the product is serving as a replacement for an existing light and there is no ground 

wire, do not install the product. First install the appropriate supply leads.
If no ground wire is connected, there will be voltage applied to the metal product 

housing in the event of an error. This poses a risk of fatal injury due to electric shock!
Make sure that the cables are not bare for too long as this may cause short-circuiting.
Make sure that all screw connections are tight.

•  Insert a suitable light bulb (not included) into the socket. Observe the information contained 

under Technical Data.

•  Item no. 559521: Make sure that the rectangular rubber gasket is fitted correctly, then insert 

the glass pane. Hold the pane until the next step to prevent it from falling.

  Item no. 559523: Insert the glass dome into the cover. 

Make sure that the cables are not squeezed, bent or damaged in any other way. Do 

not exert any force when installing the product.

•  Item no. 559521: Fasten the cover to the base unit with the two flat-head screws.
  Item no. 559523: Fasten the cover incl. glass dome to the base unit with the two flat-head 

screws.

•  Turn on power to the circuit and check to see if the product works. 

If the light bulb does not light up, cut the power supply immediately (remove the fuse 

or turn off the circuit breaker).
Then check the connection to the power circuit.
In case of doubt, contact a professional (i.e. an electrician).

Replacing luminary         

Before replacing the luminary, let the product cool sufficiently. If the luminary is not 

cooled down sufficiently and you touch it, there is a risk of burning!

•  Make sure the product is turned off.
•  Loosen the two flat-head screws and remove the cover incl. frosted glass. Hold the cover and 

frosted glass to prevent them from falling.

•  Remove the defective luminary and insert a new one.
•  Item no. 559521: Make sure that the rectangular rubber gasket is fitted correctly, then insert 

the glass pane. Hold the pane until the next step to prevent it from falling. Fasten the cover 

to the base unit with the two flat-head screws. 

  Item no. 559523: Fasten the cover incl. glass dome to the base unit with the two flat-head 

screws. 

Maintenance and cleaning         

Never use aggressive cleaning agents or chemical solutions, as such would 

damage the housing (discolourations).
Never point a water jet, for example such of high-pressure cleaning equipment, at 

the lamp, as that could damage the seals!

•  Besides occasional cleaning, the device is maintenance-free.
•  Turn off the product and let it cool down sufficiently before cleaning.
•  Use a clean, soft and dry cloth to clean the housing. For more stubborn dirt, slightly moisten 

the cloth with a little lukewarm water.

•  Do not apply too much pressure to the housing or frosted glass as doing so could cause 

scratching.

Disposal         

Electronic devices are recyclable waste and must not be disposed of in the 

household waste.
At the end of its service life, dispose of the product according to the relevant 

statutory regulations.
You  thus  fulfil  your  statutory  obligations  and  contribute  to  the  protection  of  the 

environment.

Technical data         

Item no.

559521

559523

Operating voltage

220 – 240 V/AC, 50 Hz

Output

max. 40 W

max. 40 W

Socket

E27

Operating / storage conditions

-20 to +50 ºC, <70 % RH

Protection type

IP54

Protection class

I

Materials

Die-cast aluminum, frosted glass

Dimensions

(W x H x D) 234 x 100 x 80 mm (Ø x H) 190 x 105 mm

Weight

1.25 kg

880 g

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data 

processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the 

technical status at the time of printing.

© Copyright 2014 by Conrad Electronic SE. 

V2_0814_02-KV

Summary of Contents for 559521

Page 1: ...luss nur eine geeignete Netzzuleitung die fest verlegt ist Zum Ein und Ausschalten des Produkts ist ein passender Schalter erforderlich Das Produkt muss in der bauseitigen Unterverteilung mit einer 10...

Page 2: ...erung herausdrehen oder Sicherungsautomat abschalten berpr fen Sie danach den Anschluss der Netzzuleitung Wenden Sie sich im Zweifelsfall an einen Fachmann z B Elektriker Leuchtmittel wechseln Lassen...

Page 3: ...le switch is required for turning the product on and off The product must be secured via an existing sub distribution unit with a 10 16A fuse This setup requires the installation of an upstream residu...

Page 4: ...ker Then check the connection to the power circuit In case of doubt contact a professional i e an electrician Replacing luminary Before replacing the luminary let the product cool sufficiently If the...

Page 5: ...interrupteur appropri est n cessaire pour allumer et teindre le produit Le produit doit tre prot g par un fusible 10 16Adans la distribution secondaire du b timent Tout d abord un disjoncteur d tecte...

Page 6: ...ique d visser le fusible ou couper le fusible percuter Ensuite v rifiez le raccordement du c ble d alimentation En cas de doute consultez un technicien sp cialis par exemple un lectricien Remplacement...

Page 7: ...ktrische leiding Voor het aan en uitzetten van de lamp is een geschikte schakelaar nodig Het product moet in de verdeelkast van de klant gezekerd worden met een 10 16A zekering Deze opstelling vereist...

Page 8: ...zekeringautomaat uitschakelen Controleer daarna de aansluiting van de elektrische snoer Raadpleeg in geval van twijfel een vakman bijv een elektricien Lampen vervangen Laat het product voordat u een l...

Reviews: