5
7 Placing and mounting
7.1 Finding a suitable location
Finding a suitable location determines the effectiveness and accuracy of the product.
Select a location that is not directly exposed to air-conditioning and cooling fans.
7.2 Mount using the hanging holes
Using the hanging holes and suitable screws you can hang the product on a wall.
If necessary, drill holes and insert wall plugs.
WARNING! Risk of electric shock or injury!
Before drilling, check for concealed wires or pipes beneath the surface.
7.3 Mount on a tripod
Attach the product to a tripod using the tripod thread.
7.4 Mount using the adhesive mounting plate
Using the adhesive mounting plate, you can hang the product on a wall.
To install:
1. Clean the surface to which you intend to stick the mounting plate. Make sure it is free of
grease and oil.
2. Remove the protective backing from the mounting plate.
3. Stick the mounting plate to the surface. Remove any air trapped underneath the plate.
4. Insert suitable screws into the threads in the mounting plate. Make sure they sit tight.
5. Hang the product using the hanging holes in the product casing.
8 Setting up the power supply
You can power the product via battery or a USB power supply.
8.1 Powering via USB
To power the product via USB, connect a USB power supply (5 V/DC, min. 500 mA) to the
USB-C™ port on the product.
8.2 Installing batteries
Note:
If an insulating strip protrudes from the battery compartment, batteries are installed
already. Pull the strip out to establish the power supply.
P
RECONDITIONS
:
a
Prepare the required number of batteries of the correct type as stated in the section
“Technical data”.
1. Unlock the battery compartment cover and remove it.
2. Insert the batteries into the battery compartment observing the polarity markings in the
compartment.
3. Attach the compartment cover and lock it. If a seal is present, make sure it sits correctly
and you do not damage it when attaching the cover.
9 Switching on and off
1. To switch on, move the switch
On/Off
to
On
.
2. After use, move the switch
On/Off
to
Off
to switch off.
10 Configuring
Available settings:
Main setting
Display indicator
Settings
Temperature unit
F1
°C, °F
Volume
F4
Low to high, muted
Backlight
F5
On, Off
Language
F6
CH: Chinese
EN: English
Output signal type selection
(for external circuit)
F7
S1: Switch mode
S2: Pulse mode
To adjust a setting:
1. Press the button
SET
to enter the configuration mode.
2. Keep pressing the button
SET
until the display indicator as shown in the above table ap-
pears.
3. Use the navigation button
|<<
or
>>|
to adjust settings.
4. Press the button
SET
to save.
Next:
To return to operation mode, keep pressing the button
SET
until the display leaves the
configuration mode.
11 Measuring temperature
11.1 Operating modes
Mode
Application
How it works
Temperature range
Working
Measure surface
temperature.
The temperature reading shows
on the display.
The user is informed of normal
or abnormal temperature read-
ings.
The measured temperature is
compared against the set tem-
perature threshold. If the reading
exceeds the threshold the user is
alerted.
Measuring Range:
+35 to +42 °C
Alert range:
+37 to +38 °C
Surface
Measure surface
temperature.
Example: food
The temperature reading shows
on the display.
Measuring Range:
0 to +50 °C
Count
Count every read-
ing.
Every successful measurement
increases the counter (n+1). The
counter is displayed.
11.2 Selecting an operating mode
To select a mode:
1. Keep pressing the button
SET
until
F2
appears on the display.
2. Use the navigation button
|<<
or
>>|
to select a mode: working mode (display: blank),
counting mode (display:
Count Mode
), or surface mode (display:
Surface Mode
).
3. Press the button
SET
to save.
Next:
To return to operation mode, keep pressing the button
SET
until the display leaves the
configuration mode.
11.3 Measuring temperature in working mode
11.3.1 Setting the temperature alarm threshold
After setting the temperature alarm threshold an audible alarm sounds when a temperature
reading is equal to or exceeds the threshold.
To set the threshold:
1. Keep pressing the button
SET
until
F3
appears on the display.
2. Use the navigation button
|<<
or
>>|
to set the temperature threshold (+37 to +38 °C).
3. Press the button
SET
to save.
Next:
To return to operation mode, keep pressing the button
SET
until the display leaves the
configuration mode.
11.3.2 Measuring temperature
Measure temperature in the working mode range.
P
RECONDITIONS
:
a
(If you have moved the product to a new location) the product was given at least 30
minutes to adjust to the new ambient conditions.
a
You have set the temperature alarm threshold.
1. Activate the working mode (display: blank).
2. Approach the sensor with the object. Maintain about 5 – 10 cm between object and
sensor.
à
The display shows the measured temperature.
à
The temperature evaluation is read aloud.
à
If a BEEP sounds and the indicator lights are GREEN: Reading is below the threshold
à
If the ALARM sounds and the indicator lights FLASH RED: Reading is equal or above
the threshold. This status will reset after a few seconds.
à
If the display shows
LO
(lower end) or
HI
(upper end) and an audible alert sounds:
the reading is out of range
11.4 Measuring surface temperature
Measure the surface temperature of an object.
P
RECONDITIONS
:
a
(If you have moved the product to a new location) the product was given at least 30
minutes to adjust to the new ambient conditions.
1. Activate the surface mode (display:
Surface Mode
).
2. Approach the sensor with the object. Maintain about 5 – 10 cm between object and
sensor.
à
The display shows the measured temperature.
à
The temperature is read aloud.
à
A beep sounds and the indicator lights light up green.
à
If the display shows
LO
(lower end) or
HI
(upper end) and an audible alert sounds:
the reading is out of range