BASETech 1586224 Operating Instructions Manual Download Page 6

c) Enable/disable target laser

The target laser can be switched on and off. When the laser is switched on, the laser symbol 

(triangle with radiation symbol) is shown on the display.

•  Press and hold the 

Mode

 button for 3 seconds, to enter settings mode.

•  Release the 

Mode

 button again to enter settings mode for the target laser.

 

• 

To disable the laser, hold down the trigger (1) until "0" appears in the LCD display. To enable 

the  laser,  hold  down  the  trigger  (1)  until  "1"  appears  in  the  LCD  display.  The  laser  will 

automatically be turned on when you take a measurement.

•  The target laser is automatically turned on when you take a measurement as long as the 

trigger (1) is kept pressed, if "1" was selected. The measuring process takes place without 

turning on the target laser support, if set to "0".

•  Press and hold the 

Mode

 button for 3 seconds to confirm the setting.

Troubleshooting

Problem

Cause

Solution

Blank display.

The product is switched off.

Press the trigger button (1) 

to switch the product on.

Battery too weak.

Replace the battery.

The low battery 

indicator (F) will appear 

on the display.

Battery weak.

Replace the battery.

No temperature is 

measured.

Malfunction.

Briefly press the trigger 

button (1) and start the 

measurement process 

again.

"Hi" appears on the 

display.

The temperature of the 

measured object exceeds the 

measuring range (> +350 °C).

Observe the measuring 

range.

"Lo” appears on the 

display.

The temperature of the 

measured object is below the 

measuring range (<-50 °C).

Observe the measuring 

range.

Care and cleaning

•  Before cleaning the product, disconnect it from the power supply by removing the battery.
•  Do not immerse the product in water.
•  Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these may 

damage the housing or cause the product to malfunction.

•  Remove loose particles from the lens with clean compressed air, and then wipe off any 

remaining residue with a fine lens brush. Clean the surface of the lenses using a lens cloth 

or a soft, lint-free cloth. The cloth can be moistened with water or a lens cleaning solution 

to remove fingerprints and other residues. Do not use a rough, fluffy cloth to clean the lens. 

Avoid applying too much pressure when cleaning the lens.

•  Use a dry, lint-free cloth to clean the product housing.

Disposal

a) Product

  Electronic devices are recyclable waste and must not be placed in household waste. 

At the end of its service life, dispose of the product in accordance with applicable 

regulatory guidelines.

 

If a battery is inserted, remove it and dispose of it separately from the product.

b) Batteries

  You are required by law to return all used batteries (Battery Directive). Batteries 

must not be placed in household waste.

 

Batteries containing hazardous substances are labelled with this symbol to indicate 

that disposal in household waste is forbidden. The abbreviations for heavy metals 

in batteries are: Cd = Cadmium, Hg = Mercury, Pb = Lead (indicated on the battery, 

e.g. below the trash icon on the left).

Used batteries can be returned to local collection points, our stores or battery retailers.

You thus fulfil your statutory obligations and contribute to protection of the environment.

Technical data

Temperature measuring range

Accuracy

-50 to -19 °C (-58 to -2.2 °F)

± 5 °C

-20 to 79 °C (-5 to 174.2 °F)

± 4 °C

+80 to +149 °C (+176 to +300.2 °F)

± 3 °C

+150 to +350 °C (+302 to +662 °F) 

±(3% of the measured value or +1 °C)

Operating voltage .........................

9 V/DC block battery (1 included in delivery contents)

Current consumption ....................

30 mA (with display lighting and target laser switched on)

Battery life .....................................

20 hours (with backlight and target laser)

Standby power consumption ........

3.3 µA (when switched off)

Temperature display range ...........

-50 to +350 °C (-58 to +662 °F)

Resolution  ....................................

0.1 °C /°F

Measuring range indicator ............

Temperature too high "Hi"/temperature too low "Lo"

Measurement value fixing

 .............

Yes, measurement values are fixed in the display

Switch temperature  

units between ...............................

°C/°F

Emissivity ......................................

0.95 fixed (non-adjustable)

IR measuring spot size .................

Approx. 12:1 (DS)

Spectrum (IR)

 ............................... 8 -14 µm

Response time .............................. 1 second
Laser class ................................... 2
Laser output power .......................

< 1 mW

Laser wavelength ......................... 654 nm
LCD display .................................. 23.5 x 24 mm
Display backlight ...........................

Yes, (white)

Battery level indicator ................... Yes, with 6.5 V ~ 7.0 V
Automatic power off ......................  after 10 seconds of inactivity
Operating conditions .....................

 0 to +50 °C, 10 – 80 % relative humidity (non-condensing)

Storage conditions ........................

 -10 to +60 °C, 10 – 80 % relative humidity 

 

(non-condensing)

Dimensions (L x W x H)

 ................ 153 x 72 x 42 mm

Weight .......................................... 115 g

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 
All rights including translation reserved. Reproduction by any method, (e.g. photocopying, microfilming, or capture in 

electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited. 

This publication represent the technical status at the time of printing.

Copyright 2018 by Conrad Electronic SE. 

  

*1586224_v2_0118_02_DS_m_4L_(1)

Summary of Contents for 1586224

Page 1: ...nden sich Laserhinweisschilder in verschiedenen Sprachen Sollte das Hinweisschild auf dem Laser nicht in Ihrer Landessprache verfasst sein befestigen Sie bitte das entsprechende Schild auf dem Laser Vorsicht wenn andere als die hier in der Anleitung angegebenen Bedienungseinrichtungen benutzt oder andere Verfahrensweisen ausgeführt werden kann dies zu gefährlicher Strahlungsexposition führen Bedie...

Page 2: ...öser 1 um das Infrarot Thermometer einzuschalten Das Produkt muss sich erst an die Umgebungstemperatur anpassen um genaue Messwerte liefern zu können Warten Sie bei einem Standortwechsel bis sich das Produkt an die neue Umgebungstemperatur angepasst hat d Messen von Oberflächentemperaturen Für eine Messung richten Sie den Infrarotsensor 2 und die Laseraustrittsöffnung 3 am besten senkrecht auf das...

Page 3: ...sser oder einer Linsenreinigungsflüssigkeit befeuchtet werden Verwenden Sie kein raues fusseliges Tuch um die Linse zu reinigen Vermeiden Sie übermäßigen Druck bei der Reinigung Verwenden Sie zum Reinigen des Gehäuses ein trockenes faserfreies Tuch Entsorgung a Produkt Elektronische Geräte sind Wertstoffe und gehören nicht in den Hausmüll Entsorgen Sie das Produkt am Ende seiner Lebensdauer gemäß ...

Page 4: ... in your local language attach the appropriate sign to the laser Caution Using equipment or procedures other than those described in these instructions could lead to exposure to dangerous radiation Operating instructions Basetech IR thermometer 350 C 12 1 Item no 1586224 Intended use The infrared thermometer is a measuring device for contactless temperature measurement It determines the temperatur...

Page 5: ...or 2 and the laser outlet 3 preferably perpendicular to the object to be measured Make sure that the object to be measured is not smaller than the product IR measuring spot see e IR measuring spot size distance to spot ratio D S Press the trigger 1 and hold it down while it takes measurements and until the measured value in the LCD display 4 has stabilized SCAN D will appear on the display while t...

Page 6: ... be placed in household waste At the end of its service life dispose of the product in accordance with applicable regulatory guidelines If a battery is inserted remove it and dispose of it separately from the product b Batteries You are required by law to return all used batteries Battery Directive Batteries must not be placed in household waste Batteries containing hazardous substances are labell...

Page 7: ...aîner un rayonnement laser dangereux Cet appareil est équipé d un laser de classe 2 L étendue de la fourniture comprend des panneaux d indication laser en différentes langues Si le panneau monté sur le laser n est pas rédigé dans la langue de votre pays placez y le panneau correspondant Attention L utilisation de dispositifs de commande autres que ceux indiqués dans ce mode d emploi ou l applicati...

Page 8: ...ndroit attendez que le produit se soit adapté à la nouvelle température ambiante d Mesure des températures de surface Pour effectuer une mesure dirigez le capteur infrarouge 2 et l orifice de sortie du laser 3 de préférence perpendiculairement sur l objet à mesurer Veillez à ce que l objet à mesurer ne soit pas plus petit que le spot de mesure IR de l appareil voir également le chapitre e Rapport ...

Page 9: ...u pelucheux pour nettoyer la lentille Durant le nettoyage évitez d appliquer une pression excessive Pour nettoyer le boîtier utilisez un chiffon sec et non pelucheux Élimination des déchets a Produit Les appareils électroniques sont des matériaux recyclables et ne doivent pas être éliminés avec les ordures ménagères À la fin de sa durée de vie mettez au rebut l appareil conformément aux dispositio...

Page 10: ...op de laser niet in uw landstaal is bevestig dan het juiste bordje op de laser Voorzichtig als er andere dan de in deze handleiding vermelde besturingen of methodes worden gebruikt kan dit tot gevaarlijke blootstelling aan straling leiden Gebruiksaanwijzing Basetech IR thermometer 350 C 12 1 Bestelnr 1586224 Doelmatig gebruik De infraroodthermometer is een meetapparaat voor het contactloos meten v...

Page 11: ...Het product moet zich eerst aanpassen aan de omgevingstemperatuur om nauwkeurig te kunnen meten Wacht als u van standplaats verandert totdat het product zich aan de nieuwe omgevingstemperatuur heeft aangepast d Meten van oppervlaktetemperaturen Voor een meting richt u de infraroodsensor 2 en de laseruitgang 3 bij voorkeur verticaal op het meetobject Let erop dat het meetobject niet kleiner is dan ...

Page 12: ...water of een lenzenschoonmaakvloeistof bevochtigd worden Gebruik geen ruwe pluizige doek om de lens te reinigen Druk bij de reiniging niet te hard op de lens Gebruik voor het reinigen van de behuizing een droog pluisvrij doekje Afvoer a Product Elektronische apparaten zijn recyclebare stoffen en horen niet bij het huisvuil Voer het product aan het einde van zijn levensduur volgens de geldende wett...

Reviews: