BASETech 1499833 Operating Instructions Manual Download Page 4

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in 

electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. 

This publication represents the technical status at the time of printing.
Copyright 2016 by Conrad Electronic SE. 

  

*1499833_V1_1116_02_LS_m_en

Parts and operating elements

a) 

Dehumidifier (back and front)

b) Water tank

1

3

2

4

5

6

7

12

9

10

8

18

13

14

17

15

16

11

1  Water tank (removable)
2  Air intake grid
3  On/off switch
4  Handle

Dry air output grid (on both sides)

6  Power indicator

 ON

7  Control indicator FULL

 (full water tank)

 button

9  Display
10 

 button

11  Connection socket 12 V/DC, 6 A
12  Low-voltage plug
13  Power adapter
14  Power plug
15  Nonslip rubber feet (bottom)
16  Water outlet with plug
17  Float
18 

Water inlet

Operation

a) Setting up and connecting

  The dehumidifier may only be operated on a dry, even and solid surface to prevent 

tipping.

• 

Make sure the dehumidifier is switched off. The on/off switch (3) may not be in position  . 

Make sure the water tank (1) is secure in its attachment. 

• 

Fully unwind the power cable and connection cable. 

• 

Connect the low-voltage plug (12) to the connection socket 12 V/DC, 6 A (11). 

• 

Connect the power cable to the socket on power adapter. 

• 

Connect the power plug (14) to a suitable wall outlet. 

b) Switching on/off

• 

Switch the dehumidifier with the on/off switch to position  . The power indicator 

ON

 (6) lights 

up and the dehumidifier begins dehumidifying. The dehumidifier detects the current room 

humidity and shows it on the display (9) after a few seconds.

• 

Switch  off  the  dehumidifier  after  use.  The  display,  power  and  control  indicator  go  out. 

Disconnect the mains plug from the wall socket.

c) Setting the air humidity level

• 

The  integrated  hygrostat  regulates  the  humidity  of  the  sucked-in  room  air.  When  the 

actual value exceeds the desired humidity value by approx. 5 %, the dehumidifier turns on 

dehumidification mode automatically. When the actual value deceeds the desired value, the 

dehumidifier turns off dehumidification mode.

• 

Use  the 

  (8)  or 

  (10)  buttons  to  set  the  desired  humidity  between  20  to  80  %  in 

increments of 5 %. The set value flashes on the display for a few seconds. The display then 

continues displaying current room humidity.

The factory default setting of the desired value is 50 %.
Switching the dehumidifier off and on again using the on/off switch resets the desired 

humidity value to the default factory setting.

d) 

Emptying the water tank

• 

Dehumidification mode is interrupted when the water tank is full. 
The power indicator 

ON

 (6) goes out and the control indicator 

FULL

 (7) lights up. 

• 

Switch off the dehumidifier using the on/off switch and unplug the mains plug.

• 

Carefully remove the full water tank (1) from the attachment. 

• 

Remove the plug (16) and empty the water tank via the water outlet.

• 

After emptying, reinsert the plug and fully reinsert the water tank to its attachment. The water 

tank clicks into place in its attachment.

Make sure that the float (17) (overflow protection) is correctly inserted in the back of 

the water tank. Otherwise the water tank may overflow. 

Cleaning and care

• 

Under no circumstances use aggressive cleanings agents, cleaning alcohol or other chemical 

solutions since these can penetrate the housing or impair functionality.

• 

Always turn off the device before cleaning and disconnect the mains plug from the mains 

socket.

• 

Empty the water tank before cleaning (see section “d) Emptying the water tank”). Rinse the 

water tank with lukewarm water. Do not use any coarse sponge. Dry well before returning to 

the attachment.

• 

Use a dry, soft, clean cloth to clean the housing. Do not apply too much pressure to the 

housing to prevent scratching.

• 

Use a long-haired, soft, clean brush to remove the dust from the air grids (2, 5).

Disposal

  Electronic  devices  are  recyclable  waste  and  must  not  be  disposed  of  in  the 

household waste. At the end of its service life, dispose of the product in accordance 

with applicable regulatory guidelines.

You thus fulfill your statutory obligations and contribute to the protection of the environment.

Technical data

a) 

Dehumidifier

Input voltage/current ..................... 12 V/DC, max. 6 A
Power consumption ...................... 72 W
Standby power consumption ........< 1 W
Dehumidifying capacity ................. approx. 750 ml / 24 h at +30 °C / 80 % relative humidity
Water tank capacity ...................... approx. 2 l
Water tank power-down ................ at approx. 1.5 l
Room size ..................................... < 20 m²
Noise exposure ............................. < 45 dB

Operating conditions

 ..................... +15 to +40 °C, 20 – 85 % relative humidity

Storage conditions ........................ -10 to +50 °C, 0 – 85 % relative humidity
Dimensions (W x H x D) ............... 223 x 351 x 181 mm
Weight .......................................... 2.1 kg

b) Power adapter

Input voltage/current ..................... 100 - 240 V/AC, 50/60 Hz, 2.5A
Output voltage/current .................. 12 V/DC, 6 A
Protection class ............................ II
Cable length ................................. approx. 1.5 m

Summary of Contents for 1499833

Page 1: ...umen kleiner als 20 m Der Luftentfeuchter arbeitet mit einem thermo elektrischen Peltier Modul und ist somit sehr leise im Vergleich zu kompressorbetriebenen Ger ten Der Hygrostat sorgt f r eine berw...

Page 2: ...n 5 Schritten ein Auf dem Display blinkt der eingestellte Wert f r einige Sekunden Danach wird wieder die aktuelle Raumluftfeuchtigkeit dauerhaft angezeigt Die Werkeinstellung des Sollwerts betr gt 50...

Page 3: ...nks to electrothermal Peltier technology the dehumidifier is very quiet compared to compressor powered devices The hygrostat monitors the relative humidity of sucked up room air The dehumidifier turns...

Page 4: ...display for a few seconds The display then continues displaying current room humidity The factory default setting of the desired value is 50 Switching the dehumidifier off and on again using the on of...

Page 5: ...t sert d shumidifier des petites pi ces plus petites que 20 m Le d shumidificateur fonctionne avec un module lectrothermique Peltier et est ainsi peu bruyant en comparaison avec des appareils fonction...

Page 6: ...humidit de l air souhait e dans une plage s levant de 20 80 par tape de 5 La valeur r gl e clignote sur l affichage pendant quelques secondes Ensuite l humidit de l air ambiant actuelle est indiqu e e...

Page 7: ...ner dan 20 m De luchtontvochtiger werkt met een thermo elektrische Peltier module en is dus zeer stil in vergelijking met apparaten met een compressor De hygrostaat controleert de relatieve luchtvocht...

Page 8: ...knippert enkele seconden op het display Daarna wordt de huidige luchtvochtigheid van de ruimte weer continu getoond De fabrieksinstelling van de gewenste waarde is 50 Als de luchtontvochtiger met de...

Reviews: