background image

Baseline® Push / Pull Dynamometers 

 

User’s Guide 

 
 

 

 

 

6

 

4.3 Menu navigation basics 

Most of the dynamometer

’s various functions and parameters are configured through the main menu. To 

access the menu press 

MENU

. Use the 

UP

 and 

DOWN

 keys to scroll through the items. The current 

selection is denoted with clear text over a dark background. Press 

ENTER

 to select a menu item, then 

use 

UP

 and 

DOWN

 again to scroll through the sub-menus. Press 

ENTER

 again to select the sub-menu 

item.  
 
For parameters that may be either selected or deselected, press 

ENTER

 to toggle between selecting and 

deselecting. An asterisk (

*

) to the left of the parameter label is used to indicate when the parameter has 

been selected. 
 
For parameters requiring the input of a numerical value, use the 

UP

 and 

DOWN

 keys to increment or 

decrement the value. Press and hold either key to auto-increment at a gradually increasing rate. When 
the desired value has been reached, press 

ENTER

 to save the change and revert back to the sub-menu 

item, or press 

ESCAPE

 to revert back to the sub-menu item without saving. Press 

ESCAPE

 to revert one 

step back in the menu hierarchy until back into normal operating mode. 
 
Refer to the following sections for details about setting up particular functions and parameters. 
 
 

5   OPERATING MODES 

 

Caution! 

In any operating mode, if the capacity of the instrument has been exceeded by more than 110%, 
the display will show “OVER” to indicate an overload.  

 
Three operating modes are possible. To cycle between the modes, press 

PEAK

 while in the home 

screen. 

 
5.1 Real time (RT) 

The primary reading corresponds to the live measured reading.  
 

5.2 Peak Compression (PC) 

The primary reading corresponds to the peak push reading observed. If the actual force decreases from 
the peak value, the peak will still be retained in the primary reading area of the display. Pressing 

ZERO

 

will reset the value. 
 

5.3 Peak Tension (PT) 

Same as Peak Compression, but for pull forces. 
 
 

6   CHANGING THE UNITS  

 
To change the measuring unit, select 

Units

 from the menu. The display appears as follows: 

 

 

 
The dynamometer will always power on with the unit selected. 

UNITS 

 

    * 

lbF

  

      kgF 
      N 

Summary of Contents for 12-0340

Page 1: ...Push Pull Dynamometers 12 0340 12 0341 12 0342 12 0343 User s Guide...

Page 2: ...ns are also provided For additional information or answers to your questions please do not hesitate to contact us Our technical support and engineering teams are eager to assist you Before use each pe...

Page 3: ...must be powered off before the housing is opened 4 Always consider the characteristics of the sample being tested before initiating a test A risk assessment should be carried out beforehand to ensure...

Page 4: ...ndicator is present 5 When battery life drops to approximately 2 the indicator from step 4 will be flashing Several minutes after timing depends on usage and whether the backlight is turned on or off...

Page 5: ...to withstand the load during a test A mating dowel pin should be used see illustration below An additional two holes are supplied for metric screws These holes are designed to accommodate screws in or...

Page 6: ...wn depending on power conditions Refer to the Power section for details 5 Pull push indicator indicates a push direction indicates a pull direction 4 2 Controls Primary Label Primary Function Secondar...

Page 7: ...e and revert back to the sub menu item or press ESCAPE to revert back to the sub menu item without saving Press ESCAPE to revert one step back in the menu hierarchy until back into normal operating mo...

Page 8: ...Applies to the primary reading on the display Available settings 1 2 4 8 16 32 64 128 256 512 1024 It is recommended to keep the current reading filter at its lowest value for best performance and th...

Page 9: ...in each direction 3 To escape the Calibration menu at any time press ESCAPE The display appears as follows Selecting Cancel will revert back to the Calibration setup Selecting Exit without saving will...

Page 10: ...as follows Apply a weight equal to the full scale of the instrument then press ENTER 9 After displaying Please wait the display appears as follows Remove the load applied in Step 8 leave the fixtures...

Page 11: ...s follows Press ENTER 12 The display appears as follows Reverse the orientation of the load cell shaft by rotating the dynamometer 180 degrees Press DIRECTION to invert the display Then attach weight...

Page 12: ...winging oscillating or vibrating in any manner Then try again The calibration weight does not match the set value The entered calibration point is too close to the previous point CALIBRATION TENSION L...

Page 13: ...ettings select Backlight from the menu The display appears as follows Select Off for the backlight to be off upon powering on the dynamometer Select On for the backlight to be on upon powering on the...

Page 14: ...ue is Real Time 9 5 Restore Default Settings Default factory settings can be restored by selecting Restore Defaults from the menu The settings may be found in the Specifications section The screen app...

Page 15: ...12 0341 0 7 lb 0 33 kg 12 0342 12 0343 0 9 lb 0 41 kg Environmental requirements 40 100 F max 93 humidity non condensating Warranty 3 years see individual statement for further details 10 2 Factory De...

Page 16: ...Baseline Push Pull Dynamometers User s Guide 15 10 4 Dimensions IN MM...

Page 17: ...Baseline Push Pull Dynamometers User s Guide 16 NOTES...

Page 18: ...lic Push Pull Dynamometer Can be used with lift platform to conduct muscle strength and functional capacity tests Model lbF kgF N 12 0340 50 x 0 05 25 x 0 02 250 x 0 2 12 0341 100 x 0 1 50 x 0 05 500...

Reviews: