background image

5

Maintenance

Electric Shock Is Life-threatening!

Before performing any operation on the device, please unplug the power plug from the 

socket. Do not bypass any electrical safety devices!

Inhalation Of Ozone Can Cause Injury!

After the equipment stops running, please wait for a while to ensure that the ozone 

concentration is lower than the specified value, and then perform maintenance and 

cleaning.

Please perform regular maintenance and maintenance to ensure the normal operation 

and trouble-free operation of the equipment.

The type and frequency of maintenance tasks basically depend on the operating 

environment and the time and type of use.

During use, dust and moisture will accumulate inside or inside the component, which 

may affect its function and efficiency.

In a dusty room or after repairing a fire (high humidity level), inspection and 

maintenance should be carried out immediately.

!

The basic principles for determining equipment operation and maintenance intervals:

often

Per hour

1-2 times a week

In an overly dirty environment

In a humid room

Regardless of the operating conditions described, you should perform maintenance if one or 

more of the following signs appear:

The noise level increases when the fan is running

The substances produced during the ozone production process gradually disappear.

Severely polluted soft magnetic stickers

Dirty electrodes (identifiable by hissing sound)

House Cleaning

Clean the case with a soft, damp, lint-free cloth. Make sure that no moisture enters the enclosure. 

Prevent electrical components from getting wet. Do not use any harsh cleaning agents, such as cleaning 

sprays, solvents, alcohol-based cleaning agents, or abrasives to soak the cloth.

Cleaning

Within the framework of regular maintenance work, it is not only necessary to check the normal 

condition of the equipment and its accessories, but also to thoroughly clean the equipment and its 

components.

Proceed As Follows:

Remove the screws on the dust cover.

Disassemble and clean the fan. Always check whether the fan is working properly. If it is only slightly 

contaminated, you can use a vacuum cleaner or a tap to clean it. If the contamination is serious, 

clean the reaction generator with a soap solution. After cleaning, insert the fan only after it is 

completely dry!

Remove the shell.

Clean the fan

1.

2.
3.

Summary of Contents for UVC3

Page 1: ...Installation Operations Manual UVC3 Pro Ozone Generator Tel 1 888 641 8862 Web www baseaire com E mail sales baseaire com...

Page 2: ...Table Of Contents Device Description Operation Mistakes and shortcomings Maintenance Transportation And Storage Technical Annex Electrical wiring diagram Limited Warranty 01 02 04 05 06 07 08 09...

Page 3: ...accordance with applicable safety standards and bears the CE mark Ozone is a very powerful oxidant with high reaction potential This makes it an effective agent for decomposing destructive substances...

Page 4: ...ion Gears The default gear for starting is 1 gear and the fan and ozone are 5 gears The fan has no thyristor speed regulation the delay after detecting the zero crossing determines the size of the gea...

Page 5: ...the processing time Type Of Smell The treatment time is in min 3 Room size 30 m 15 20 20 40 40 40 240 360 360 3 3 30 m Room size 60 m 30 40 40 60 60 60 480 720 720 Disinfectant Car Interior From Anim...

Page 6: ...fuse does not need to be repaired but it must be replaced at any time In most cases the fuse is triggered by a serious technical failure Please authorized service personnel to replace each fuse Let c...

Page 7: ...Regardless of the operating conditions described you should perform maintenance if one or more of the following signs appear The noise level increases when the fan is running The substances produced d...

Page 8: ...e always disconnect the power supply Store the Baseaire UVC3 Pro ozone generator in a dry place to avoid the influence of bad weather and cover it to protect it from invasive dust Clean Electrode The...

Page 9: ...ating Temperature Sound Pressure Level Service Life Size For Dimensions L W H Minimum Distance From Walls And Other Objects Top a Rear b Sides c Front d Value 110V 60HZ 55 130CFM 220CMH 10 000 mg h 14...

Page 10: ...8 Electrical wiring diagram...

Page 11: ...ers must log in www baseaire com to fill out the warranty Registration form and submit to BaseAire company We will receive your purchasing and installation information and save it Customers can pick u...

Page 12: ...SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE BaseAire s total liability rega...

Reviews: