Base aire UVC3 Installation & Operation Manual Download Page 5

3

Warning

The risk of ozone causing harm to the human body!

During use, if you smell ozone outside the working area, the machine must stop 

working immediately. Ventilate the room thoroughly.

!

The following values are used as a general reference for determining the processing time:

Type Of Smell

The treatment time is in min

3

Room size< 30 m

15

20

20

40

40

40-240

360

360

3

3

30 m < Room size< 60 m

30

40

40

60

60

60 - 480

720

720

Disinfectant

Car Interior

From Animals, Cooking And Waste

Burning / chemical

The Musty Smell After Water Damage

Secondary Effects Of A Burning 

Smell And Organic Matter

Amine / amide (urea), Open-chain 

Hydrocarbon Compound (e.g. 

Butyric Acid)

Amino Acids / proteins Containing 

Nitrogen And Sulfur (vomit)

Summary of Contents for UVC3

Page 1: ...Installation Operations Manual UVC3 Pro Ozone Generator Tel 1 888 641 8862 Web www baseaire com E mail sales baseaire com...

Page 2: ...Table Of Contents Device Description Operation Mistakes and shortcomings Maintenance Transportation And Storage Technical Annex Electrical wiring diagram Limited Warranty 01 02 04 05 06 07 08 09...

Page 3: ...accordance with applicable safety standards and bears the CE mark Ozone is a very powerful oxidant with high reaction potential This makes it an effective agent for decomposing destructive substances...

Page 4: ...ion Gears The default gear for starting is 1 gear and the fan and ozone are 5 gears The fan has no thyristor speed regulation the delay after detecting the zero crossing determines the size of the gea...

Page 5: ...the processing time Type Of Smell The treatment time is in min 3 Room size 30 m 15 20 20 40 40 40 240 360 360 3 3 30 m Room size 60 m 30 40 40 60 60 60 480 720 720 Disinfectant Car Interior From Anim...

Page 6: ...fuse does not need to be repaired but it must be replaced at any time In most cases the fuse is triggered by a serious technical failure Please authorized service personnel to replace each fuse Let c...

Page 7: ...Regardless of the operating conditions described you should perform maintenance if one or more of the following signs appear The noise level increases when the fan is running The substances produced d...

Page 8: ...e always disconnect the power supply Store the Baseaire UVC3 Pro ozone generator in a dry place to avoid the influence of bad weather and cover it to protect it from invasive dust Clean Electrode The...

Page 9: ...ating Temperature Sound Pressure Level Service Life Size For Dimensions L W H Minimum Distance From Walls And Other Objects Top a Rear b Sides c Front d Value 110V 60HZ 55 130CFM 220CMH 10 000 mg h 14...

Page 10: ...8 Electrical wiring diagram...

Page 11: ...ers must log in www baseaire com to fill out the warranty Registration form and submit to BaseAire company We will receive your purchasing and installation information and save it Customers can pick u...

Page 12: ...SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE BaseAire s total liability rega...

Reviews: