background image

W

arranty

The warranty card number
Model name
Serial number
Seller name

With following stated terms of warranty is familiar, functional test was
performed in my presence: 

Customer signature

W

arranty conditions

The warranty period of the product — 36 (thirty-six) months from
the date of sale.

Transportation of product must be in its original packaging or supplied one
by the seller.
The product is accepted in warranty repair only with a properly 

lled warranty

card and the presence of intact

 

stickers or labels.

The product is accepted for examination in accordance with the cases
provided

 

by law, only in the original packaging, in a full complete set,

appearance

 

corresponding to the new equipment and presence of all relevant

properly

 fi

lled documents.

This warranty is in addition to the constitutional and other consumer rights
and in no way restrict them.  

Terms of warranty

The warranty card must indicate the name of the model, serial number,
purchase date, name of the seller, seller

 

company stamp and

the

 

customer’s signature. 

Delivery to the warranty repair is carried out by the buyer himself.
Warranty repairs carried out only during the warranty period speci

ed

in the warranty card.
The service center is committed to do everything possible to carry out
the repair warranty products, up to 24

 

working days. The period spent

on the restoration of product functionality is added to the warranty period.

Summary of Contents for SH-42

Page 1: ...USER MANUAL TWO LOCKS CONTROL MODULE SH 42 ...

Page 2: ...vice description wiki bas ip com TWO LOCKS CONTROL MODULE Main feature Module supply voltage 12 V Power consumption in operating mode 1 W Standby power consumption 0 06 W Maximum current of connected load 7 A per channel Maximum constant load voltage 30 V Maximum AC load voltage 250 V Operating temperature 40 75 C Storage temperature 15 65 C Permissible humidity 20 80 Degree of protection IP30C Ov...

Page 3: ... Lock input only the first relay will act on switching For the Lock input it is necessary to use a low voltage external signal with a DC voltage from 9 to 12 V 12V DC Ground 485 485 Lock 12V DC Ground Lock SH 42 RS 485 Outdoor panel From the external signal source Relay Outputs It is possible to connect both electromagnetic and electromechanical locks to the relay outputs In this case two relays ar...

Page 4: ... Exit 2 and GND contacts 12V DC Ground 485 485 Lock Exit 1 Exit2 Fire input 12V DC Ground 485 485 Lock SH 42 module Outdoor panel Exit Button 1 Exit Button 2 12V DC Ground 485 485 Lock Exit 1 Exit2 Fire input 12V DC Ground 485 485 Lock SH 42 module Outdoor panel Exit Button 1 Exit Button 2 Fire alarm The option of connecting the exit and fire alarm buttons To connect the output control button of th...

Page 5: ...t the delay time so that it is in the range of 4 to 8 seconds If you need to use other values this time can set more or less recommended values but not less than 2 seconds The use of electromechanical locks When connecting electromechanical locks the controller must be turned to the left and the delay time is adjusted so that it is in the range of 0 5 to 1 second If necessary the time can be sligh...

Page 6: ...in the original packaging in a full complete set appearance corresponding to the new equipment and presence of all relevant properly filled documents This warranty is in addition to the constitutional and other consumer rights and in no way restrict them Terms of warranty The warranty card must indicate the name of the model serial number purchase date name of the seller seller company stamp and th...

Page 7: ...Notes EAN 5060514910559 ...

Page 8: ...www bas ip com ...