Possible Malfunctions
24 / 28
110500
EN
Malfunction
Possible Cause
Solution
The appliance does
not collect water.
Water supply valve closed.
Open the water supply
valve.
Rinse arm nozzles clogged.
Clean the nozzles and
check the rinse arms for
limestone.
Solenoid valve filter clogged. Contact technical service
to order cleaning.
Rinse pump failure.
Contact technical service
to order replacement.
Pressure switch error.
Contact technical service
to order replacement.
Incorrectly closed appliance
door.
Close the appliance door
correctly.
Washing results are
not satisfactory.
Wash arms are clogged.
Thoroughly clean the wash
arms.
Not enough washing agent
added.
Contact technical service
to request setting of the
rinsing agent dosing pump.
Filters are dirty.
Thoroughly clean the
filters.
Foaming.
Inappropriate cleaning
agent. Contact technical
service to select correct
cleaning agent.
Too much rinsing agent.
Contact technical service
to request change of
setting of the rinsing agent
dosing pump.