Installation and operation
18 / 22
1061533
EN
3. Then ignite another burner by pressing and rotating another knob anti-
clockwise.
Use the same procedure for the third burner.
NOTE!
Always start the burner adjacent to already ignited in order to transfer the
flame.
4. After the burner ignition set the gas knob in required position. Select small or big
flame (paying attention to symbols on the knob).
Replacement of burner nozzles
• The appliance is factory-prepared for operation with the gas type and pressure
specified on the rating plate.
• When required, the appliance may be set to the gas pressure available in the
installation country with use of special burner nozzles included in the delivery.
• Replacement of burner nozzles must be carried out by a qualified gas systems
installer!
• The factory-installed nozzle must be replaced with a nozzle suitable for the gas
pressure available in the installation country. For burner nozzle data, refer to
Table 1
'Gas Pressure Table / Destination Countries / Burner Nozzles'
.
• Replacement of burner nozzles must be performed for all burners.
• After the replacement place appropriate sticker on the rating plate.
• The warning instructions on the appliance should be replaced with the language
used in the installation place.
Switching the Appliance OFF
1. In order to switch the appliance off after work, rotate all gas knobs clockwise.
CAUTION!
In case of longer standstills, failures, or irregular use the gas cylinder
valve must be closed.