background image

 

Installation and operation 

14 / 22 

1061533 

EN 

of materials resistant to high temperatures), which sustain temperatures of at 
least 65°C. 

•  Maintain sufficient lateral clearance for service purposes should maintenance 

and repair works be required. 

 

 

5.2

 

Gas Connection 

 

 

CAUTION! 

All installation, connection and maintenance works for the appliance must 
be performed by the qualified gas systems installer according to the valid 
international, national and local regulations.  

 
•  The appliance is approved and by factory default prepared to operate with the 

type of gas stated on the rating plate.  

A clearance of at least 50 cm must be maintained between the gas table-top pan 

and the gas cylinder.  

WARNING!  

Keep the gas cylinder away from fire. 

 
1.  Store gas cylinders in vertical position even when empty. 

 

 

   

  Gas cylinder valve 

  Pressure controller 

  Gas hose 

  Gas cylinder 

  Hose breaking protection 

Fig. 2 

   

 

2.  Fix the appropriate pressure controller 

 to the gas cylinder 

 (Fig. 2) using 

large brass nut. . 

3.  Place the hose breaking protection 

 between the pressure controller and the 

gas hose. (as shown in Fig.) 

4.  Finally connect the gas hose 

 with the pressure controller 

. Use only 

connection hoses with DVGW certificate. 

Summary of Contents for TB1000R

Page 1: ...TB1000R TB1000PF 1061533 1061933...

Page 2: ...cher GmbH Franz Kleine Str 28 D 33154 Salzkotten Germany Phone 49 5258 971 0 Fax 49 5258 971 120 Service hotline 49 5258 971 197 www bartscher com 0063CL7046 Version 1 0 Date of preparation 2023 02 07...

Page 3: ...mity 7 3 Transport Packaging and Storage 8 3 1 Delivery Check 8 3 2 Packaging 8 3 3 Storage 8 4 Technical Data 9 4 1 Technical Specifications 9 4 2 Functions of the Appliance 10 4 3 List of Components...

Page 4: ...s included in this manual is a prerequisite for safe and proper handling of the appliance Additionally accident prevention occupational health and safety and legal regulations in force in the area the...

Page 5: ...iance 1 2 Safety instructions Safety During Operation of Gas Appliances Do not use a gas supplied appliance in the event of a malfunction or damage or in the case of a suspected malfunction or damage...

Page 6: ...left overs of food products remaining in the appliance may catch fire To avoid fire hazard clean the appliance regularly Never leave the appliance unattended especially when cooking with fats or oils...

Page 7: ...erience and or limited knowledge Children should be supervised to ensure that they are not playing with or switching on the appliance Improper Use Unintended or prohibited use may cause damage to the...

Page 8: ...tended use frying and grilling suitable food using suitable accessories grill grate grill pan The appliance may be used outdoors only 1 4 Unintended Use An unintended use may lead to personal injuries...

Page 9: ...ntroduced by the user usage of unapproved spare parts We reserve the right to introduce technical modifications to the product intended for improvement of the appliance and its performance 2 2 Copyrig...

Page 10: ...en relocating or when shipping the appliance to our service point in the case of any damages The packaging and its elements are made of recyclable materials Particularly these are plastic films and ba...

Page 11: ...Important indication operation only with liquefied gas for outdoor use only Name Gas table top grill TB1000R Art No 1061533 Material stainless steel Grill grate material stainless steel Grill grate di...

Page 12: ...s 3 Gas connection 1 4 Control pressure in mbar 50 Consumption in g hour 728 Connection value in kW 10 Dimensions W x D x H in mm 705 x 560 x 275 Weight in kg 13 7 We reserve the right to implement te...

Page 13: ...ts of the Appliance Fig 1 1 Grill frying pan 1061933 2 Thermoelement 3 Piezo igniter 4 Feet 4 pcs 5 Frame 6 U shaped gas burner 3 pcs 7 Gas controller 8 Flame cover 1061533 9 Grill grate 1061533 10 Dr...

Page 14: ...w NOTE The manufacturer disclaims all liability and provides no warranty for damages which may be attributed to non observance of regulations or incorrect installation Installation Requirements Observ...

Page 15: ...ent clearance from table edges The appliance might turn over and fall down Posi tion the appliance outdoors or i n a l arge open and well ventilated ar ea see D VGW wor ki ng sheet G 631 When setting...

Page 16: ...nd by factory default prepared to operate with the type of gas stated on the rating plate A clearance of at least 50 cm must be maintained between the gas table top pan and the gas cylinder WARNING Ke...

Page 17: ...gas hose is correctly fixed and perform the tightness test as described in section 5 4 Before Start Up Gas Pressure Table Destination Countries Burner Nozzles Destination countries Categories Gas pre...

Page 18: ...rill pan or grill grate Before Start Up DANGER Never perform the tightness test with use of open flame 1 Perform the tightness test before the gas table top grill start up 2 Make sure that the gas cyl...

Page 19: ...ill the dripping tray with small amount of water and slide it into the guides under the frame Never use the appliance without the dripping tray When using the grill grate with the appliance 1061533 do...

Page 20: ...with use of special burner nozzles included in the delivery Replacement of burner nozzles must be carried out by a qualified gas systems installer The factory installed nozzle must be replaced with a...

Page 21: ...he appliance up vapours may cause fire or explosion Do not use steel wool wire brushes nor putty knives which may leave particles of iron These materials may get oxidized and leave the appliance with...

Page 22: ...rvals All maintenance and repair works must be performed by an authorized gas specialist only To keep the appliance operational it must be subject to maintenance at least twice a year We recommend to...

Page 23: ...sible Cause Solution The burner does not ignite Damaged Piezo igniter Contact the service company Damaged thermal element Contaminated ignition plug Damaged pressure controller Empty gas cylinder Repl...

Page 24: ...ng national and local regulations To this end we recommend contacting a professional company or local authorities unit proper for utilisation matters Before disposing of the appliance make sure that t...