Installation and operation
14 / 22
1061533
EN
of materials resistant to high temperatures), which sustain temperatures of at
least 65°C.
• Maintain sufficient lateral clearance for service purposes should maintenance
and repair works be required.
5.2
Gas Connection
CAUTION!
All installation, connection and maintenance works for the appliance must
be performed by the qualified gas systems installer according to the valid
international, national and local regulations.
• The appliance is approved and by factory default prepared to operate with the
type of gas stated on the rating plate.
A clearance of at least 50 cm must be maintained between the gas table-top pan
and the gas cylinder.
WARNING!
Keep the gas cylinder away from fire.
1. Store gas cylinders in vertical position even when empty.
①
Gas cylinder valve
②
Pressure controller
③
Gas hose
④
Gas cylinder
⑤
Hose breaking protection
Fig. 2
2. Fix the appropriate pressure controller
②
to the gas cylinder
④
(Fig. 2) using
large brass nut. .
3. Place the hose breaking protection
⑤
between the pressure controller and the
gas hose. (as shown in Fig.)
4. Finally connect the gas hose
③
with the pressure controller
②
. Use only
connection hoses with DVGW certificate.