25
PROBLEM
POSSIBLE CAUSES
SOLUTION
11) Pan does not free cubes or remains in
am intermediary position.
A) Cam motor disconnected or in bad
condition.
A) y B) Connect or replace cam
motor.
ALWAYS change pin and wheel.
B) Flexible pin or cam wheel broken.
12) Pan goes up and down constantly.
A) Agitator motor micro-switch badly
connected or faulty.
A) Connect or replace micro-switch.
B) Security micro badly connected or
faulty.
B) Connect or replace micro-switch.
C) Faulty rele
C) Replace rele.
13) The evaporator gets cold. And there is A) Water supply turned off.
A) Turn on.
no water in the pan.
B) Foreign bodies in water supply.
B) Clean water entry filters.
C) The buoy wrongly positioned
C) Adjust buoy.
D) Faulty buoy micro-switch.
D) Replace micro-switch.
E) Faulty water intake electrovalve.
E) Replace electrovalve.
Summary of Contents for QUASAR 130 C
Page 6: ...6 ...
Page 8: ...8 STOCK THERMOSTAT WATER INLET ELECTRICAL CONNECTION ...