- 52 -
o
To clean the back side of the blade (1)
and the blade protective ring (3) proceed
in the following way:
-
Remove the blade protection (2)
(fig. 30);
-
Remove the sharpener from the
device (a, fig. 32);
-
Open the movable slice thickness
wall (16) using the slice thickness
adjustment (11) in order to place
the tool for blade replacement on
the blade (1) (b, fig. 32);
Fig. 32
-
Place the tool for blade replacement (b, fig. 32) on the blade (1) and adjust to the
protective ring (c, fig. 32);
-
The blade openings (d, fig. 32) must fit the two pins of the tool for blade
replacement (e, fig. 32), to achieve it, turn the blade (1) until this position is
reached;
-
Slightly screw in the two pins of the tool for blade replacement (e, fig. 32);
-
Undo the four screws (f, fig. 32) locking the blade(1) using a relevant screw driver;
-
Remove the blade (1) with the tool for blade replacement (b, fig. 32);
-
Clean the back side of the blade (1) and the blade protective ring (3) with a damp
cloth and neutral cleaning agent.
WARNING! Possible cuts danger!
The blade is extremely sharp, do not touch any edges of the blade! During
cleaning of the blade wear cut protection gloves of class 5 of DIN EN 388.
o
After cleaning, attach the blade (1) to the device using the 4 screws (f, fig. 32),
blade protecive ring (3) and blade guard (2) maintaining the correct position.