![Bartscher MFG 7341 Manual Download Page 27](http://html1.mh-extra.com/html/bartscher/mfg-7341/mfg-7341_manual_4130563027.webp)
- 60 -
a) Replacement of main burner nozzle
•
Remove all adjustment knobs and disconnect the control panel from the device
in order to obtain access to the brackets of the nozzles.
•
Remove the bolt fixing the nozzle bracket.
•
Replace the removed nozzle with the one designed for a given gas type
(nozzle data are in
table 2 “Nozzle and burner properties”
on page 54).
Tighten the nozzle.
•
Modify all burners according to the above instructions.
b) Replacement of ignition burner nozzle
Access to the ignition burner is possible only after removing the control panel.
Remove the closing nut from the ignition burner and replace or adjust nozzles
of the ignition flame accordingly to the gas type.
c) Primary air adjustment (fig. 2)
When the primary air is adjusted correctly the flame is
stable, so there will be no interruptions when the burner
is cold or back burning when the burner is hot.
The provided distance (“X”) for the primary air setting is
specified in
fig. 2
and in
table 2
. After the replacement of
nozzles check setting of primary air for all burners.
Fig. 2
d) Ignition burner adjustment
Adjust the ignition burner and see if the flame is correct and covers the thermal
element. If not, see if correct nozzles are installed (
table 2, page 54
).