- 56 -
•
Air must be taken directly from outside environment through the permanently
opened gaps or intake ducts connected with fresh air area.
•
The device must be installed in the rooms adapted for combustion gas extraction.
The installation must be realized according to the valid standards.
•
The devices belong to the following category:
Devices supplied with gas of category A
and are not designed
for connecting to the combustion gas extraction system.
•
The combustion gas produced by the devices must be removed with use of
appropriate hoods or other similar devices connected to efficient chimney stack or
directly outside.
•
If there are no such devices the fan may be used for extracting the combustion gas
directly outside of power not lower than the recommended values.
•
Before positioning the device check the dimensions and exact positions of the
electric and gas connections.
•
Locate the device in a safe place, on a level surface capable of supporting the device's
weight with the maximum amount of food products.
•
Never
place the device on a flammable surface or one sensitive to high temperatures.
•
Do not place the device near open flames, electric heaters or other heat sources.
•
Never place the device directly next to walls, furniture or other objects made of
flammable materials. Keep a minimum distance of
200 mm
from the sides and rear.
Keep a minimum distance of
600 mm
between the upper surface of the device and
surfaces located above it. Proceed according to relevant fire safety regulations.
•
If it is not possible to observe the above distances, apply protective measures
(e.g. heat-resistant coatings) that can resist temperatures of at least
65 °C
.
Use only original spare parts!
•
Regulate the level and height of the device with the adjustable legs. Large differences
in height or level may have a negative impact on the device's functioning.