50
Fault
Reason
Solution
When steam
injection is water
leaks from the tube
Water supply is closed.
The water supply
connection has not been
made properly.
The inlet water filter is
clogged with dirt
.
Open water supply.
Check water supply.
Clean the inlet water filter
.
When the oven
door is closed the
water leaks
through the seal
Dirty seal.
Damaged seal.
There is a problem with
closing the oven door.
Clean the seal with a damp
cloth.
Contact the Customer
Service.
Contact the Customer
Service.
The fan stops
during operation
Motor protection thermostat
kicked in.
The condenser motor is
damaged.
Turn off the convection
oven and allow the system
protecting the motor from
overheating to start up
again. If the fault repeats,
contact the Customer
Service.
Contact the Customer.
CAUTION!
The above cases the troubles are just examples for your orientation. If such or
similar problems occur you should immediately turn off the device and stop using
it. If the defects are not removed, you must contact directly the customer service
department or your dealer for inspection and repair. Please quote the article and
serial number of the device; this data can be found on the nameplate on the back
of the oven. Never attempt to make any repairs on your own
.