Possible malfunctions
A120788
25 / 28
EN
7
Possible malfunctions
Mögliche
The table below contains descriptions of possible causes and solutions to
malfunctions or errors during operation of the appliance. When malfunction cannot
be removed, contact the technical service.
Error
Possible Cause
Solution
The appliance is
connected to the
power supply but the
green operation
indicator light is not lit.
Incorrectly connected
plug.
Remove the plug and insert it
properly into the socket.
Main controller/time
controller is not set.
Set the main controller/time
controller.
The appliance is
connected to the
power supply, but it
does not heat up.
Temperature is not set. Set the temperature.
Damaged heater.
Contact the service company.
The appliance is
connected to the
power supply, but it
does not work.
Overheating protection
triggered.
Wait for the appliance to cool
off. Press the RESET button at
the rear side of the appliance.
If the overheating protection
triggers again, contact the
service company.
Cooking/baking effect
is not uniform.
Damaged fan.
Contact the service company.
Thermostat broken.
Contact the service company.
Top clearance between
dishes and oven sheets
is too small.
Maintain clearance of at least
40 mm.