Installation and operation
14 / 28
A120788
EN
Water connection
1. Make sure that the potable water connection is located close to the appliance.
2. Prior to establishing the water connection, flush the tube with enough water to
remove all residues of substances that might be present in the tubes, so that
they do not enter solenoid valves.
NOTE:
To provide for proper functioning and prevent limescale deposits in the
oven chamber, the appliance should be supplied with potable water, with
hardness of 0.5
–5 ° dH (German degrees). With higher values it is
necessary to install water softening system.
3. Connect the right pressure hose to the inflow pipe stub (3/4") at the rear face of
the appliance.
4. Connect the other end of the pressure hose to the cold water installation with a
stopcock.
The potable water supply should feature the
pressure between 50 kPa (0.5 bar) and 200
kPa (2 bar).
If the entry pressure exceeds 200 kPa (2
bar), install a pressure reducer.