background image

 

 

 

- 38 - 

 

Connection 

 DANGER! Electric shock hazard! 

The device can cause injuries due to improper installation! 

 

Before installation and connecting the local power grid specification should 
be compared with that of the device (see rating plate). Connect the device only 
in case of compliance! 

 

Connect the device only to properly installed single socket with 
protective terminal. 

 

 

  If during transport the device was placed horizontally, the connection may 

occur only after a period of 2 hours (built-in condensing unit). 

  

  After a power failure or if the plug is removed, the device should not be 

connected to the power supply for at least 5 minutes.  

  

  The electrical circuit in the socket must be secured to at least 16A. Only connect the 

device directly to the wall socket; do not use any extension cords or power strips.

 

 

5.2 Operation 

 

Preparation and start-up 

 

  Before first use, clean the refrigerated counter . Please refer to the guidelines in

 

Se   on 6 "C ean ng and Ma n enan e“

.

 

  Connect the device to a single, earthed socket.   

  Switch on the device using the 

ON/OFF

 network switch on the front of the device. 

The Green LED power indicator in the switch comes on. The current temperature 
inside the device is shown on the digital display.   

  Before using and placing any foodstuffs, the device should first obtain the desired 

temperature.  

 

Digital temperature control 

 

Basic settings of the temperature are pre-set and reflect the operating temperature in 
the range of 0 °C 

– 10 °C inside of the device. During normal operation of the device the 

digital display indicates the current temperature inside of the device. 

 

 

Button

 

Functions

 

  Display a required value, select parameters 

in programming mode or save the procedure

 

  Manual start of defrost

 

  In programming mode, select a parameter 

code, increase the displayed value

 

 

AUX 

In programming mode, select a parameter 
code, decrease the displayed value

 

Summary of Contents for 900T1S2

Page 1: ...Original Gebrauchsanleitung V2 0416 110156 110157 200259 57 200278 ...

Page 2: ...ty 29 3 Transport packaging and storage 30 3 1 Delivery check 30 3 2 Packaging 30 3 3 Storage 30 4 Technical data 31 4 1 Overview of parts 31 4 2 Technical specification 35 5 Installation and operation 37 5 1 Positioning and connection 37 5 2 Operation 38 6 Cleaning and maintenance 41 7 Possible Malfunctions 43 8 Waste disposal 44 Bartscher GmbH Franz Kleine Str 28 D 33154 Salzkotten phone 49 0 52...

Page 3: ...m to future owners of the device 1 Safety This device is designed in accordance with the presently applicable technological standards However the device can pose a danger if handled improperly and inappropriately All persons using the device must follow the recommendations and instructions in this manual 1 1 Safety instructions This device may only be operated in technically proper and safe condit...

Page 4: ...Ensure that no one can step on or trip over the cable The power cable must not be folded bent or tangled and must always remain fully unrolled Never place the device or other objects on the power cable Do not lay the cable over carpets or heat insulations Do not cover the cable Keep away the cable from operating range and do not dunk it into water Inspect the power cable regularly for damage Never...

Page 5: ...ice surface is hot when in use Ignoring this warning may result in burns CAUTION This symbol highlights dangerous situations which could lead to light injuries or damage malfunction and or destruction of the device NOTE This symbol highlights recommendations and information aimed for effective and trouble free device operation 1 3 Hazard sources DANGER Electric shock hazard To avoid the hazard res...

Page 6: ...follow the safety instructions below During normal use the condenser and compressor surfaces may be hot To avoid burning your palm or hands do not touch them with your bare hands Wear protective gloves WARNING Fire or explosion hazard To avoid the hazard results please follow the safety instructions below Do not store the flammable or explosive substances in the device like ether kerosene or glues...

Page 7: ...ntended only for cooling preparing and selling salads fruits vegetables and cold dishes The refrigerated counter should not be used for storing of the flammable or explosive substances in the device like ether kerosene or glues storing of pharmaceutical products or preserved blood CAUTION Any use going beyond the intended purpose and or any different use of the device is forbidden and is not consi...

Page 8: ...d by violation of advice concerning operation and cleaning use other than designed alterations made by user use of inadequate spare parts We reserve the right to make technical changes for purposes of developing and improving the useful properties 2 2 Copyright protection The instruction manual including any texts drawings images or other illustrations is copyright No part of this publication may ...

Page 9: ... packing material should be removed completely from the device before installation NOTE If you liked to dispose the packing consider the regulations applicable in your country Supply re usable packing materials to the recycling Please inspect the device upon completeness In case any part is missing please contact our customer service center immediately 3 3 Storage Keep the package closed until ins...

Page 10: ...hnical data 4 1 Overview of parts 110156 1 Worktop 2 Housing 3 Door 2 4 Air vents 5 ON OFF switch with network indicator 6 Digital temperature controller 7 Frating rack 2 8 Guides for grid racks 4 2 3 1 7 8 5 6 ...

Page 11: ... 32 110157 1 Worktop 2 Housing 3 Door 2 4 Air vents 5 ON OFF switch with network indicator 6 Digital temperature controller 7 Drawer 2 8 Frating rack 2 9 Guides for grid racks 4 3 2 7 1 8 9 5 6 ...

Page 12: ...Trough for GN containers 3 Cooling superstructure 4 Worktop 5 Housing 6 Door 2 7 Air vents 2 8 ON OFF switch with network indicator 9 Digital temperature controller 10 Frating rack 2 11 Guides for grid racks 12 Bridge 5 7 5 2 6 1 3 4 10 11 9 8 12 ...

Page 13: ...6 Door 2 2 Air vents 7 Tray without cooling 6 3 Digital temperature controller 8 Height adjustable feet 4 ON OFF switch with integrated 9 Housing network indicator light green 5 Cooling chamber lock 10 Guides 1 6 2 3 4 5 9 7 8 10 ...

Page 14: ...range 0 C 10 C Refrigerant R134a Dimensions W 900 x D 700 x H 870 mm Weight 60 2 kg Name Mini refrigerated counter 900T1S2 Code no 110157 Material Chrome nickel steel Features 1 door 2 trays Internal dimensions of each tray W 304 x D 515 x H 140 mm Ventilated cooling Electronic control Evaporation condensation Foam evaporator Capacity 260 liters Power 0 204 kW 220 240 V 50 Hz Temperature range 0 C...

Page 15: ...t 62 0 kg Accessories 5 bridges length 174 mm width 25 mm Delivery without GN containers Name Refrigerated counter 26640 Code no 200278 Material Chrome nickel steel with granite worktop Features 2 doors refrigerated each with 10 trays 600 x 400 mm spacing between trays 100 mm 6 trays without cooling dimensions 600 x 400 mm height 70 mm Ventilated cooling Electronic control Evaporation condensation...

Page 16: ...t so that there is an adequate supply of air circulation Keep a 10 cm clearance on the sides and rear and 30 cm from the ceiling or cabinets Never cover and do not block ventilation openings Do not place the device in places where there is high humidity Too much moisture can cause damage to the device The optimum operating conditions at the set device is achieved at ambient temperatures between 10...

Page 17: ...and start up Before first use clean the refrigerated counter Please refer to the guidelines in Se on 6 C ean ng and Ma n enan e Connect the device to a single earthed socket Switch on the device using the ON OFF network switch on the front of the device The Green LED power indicator in the switch comes on The current temperature inside the device is shown on the digital display Before using and pl...

Page 18: ...n start programming Return to a previous indication press both buttons to leave the programming mode and return to a previous displayed value temperature inside of the device LED indicators LED indicators on the digital display indicate the active function LED Display Meaning illuminates compressor active flashes delayed illuminates defrost in progess flashes defrost delayed illuminates Indicated ...

Page 19: ...ff using the main switch position O OFF and disconnect from the power supply pull out the plug NOTE Any water accumulated in the bottom of the device can be removed by the discharge pipe below the device Defrosting Automatic defrosting The device is automatically defrosted four times within 24 hours The clock starts upon first activation If the automatic defrosting is to be carried out at other ti...

Page 20: ...e longer the door tray is open the higher the energy consumption is In order to limit losses in the cooling process the shutter doors trays and cover raiser should be as short as possible In addition the doors trays and cover should not be opened too often In order to prevent the formation of unpleasant odors inside the refrigerated counter follow the recommended limits for the storage of food and...

Page 21: ...d to clean with natural stone Follow manufacturer s instructions The condenser CAUTION A dirty condenser has a negative impact on operation and increases energy consumption In order to maintain full efficiency of the device regularly once a week clean the condenser according to the following guidelines o Before cleaning turn the device off unplug it from the socket pull the plug o Remove the screw...

Page 22: ...eck the fuse check the device when connected to a different socket Check power supply Contact the seller Insufficient cooling capacity Improper temperature setting The device is in the thawing process Too close location to sources of heat or direct sunlight Poor air circulation around the device Device overloaded Correct temperature setting Wait until the thaw phase is complete check the cooling p...

Page 23: ...visable to contact a company which is specialized in waste disposal or just contact the local disposal service in your community WARNING To exclude any abuse and the dangers involved make the waste device unfit for use before disposal For that purpose disconnect device from mains supply and remove mains connection cable from the device CAUTION For the disposal of the device please consider and act...