Installation Instructions
20 / 32
1152263
EN
Resetting to Other Type of Gas / Required Adjustments
The appliances are set to the following gas type/category:
II2ELL3B/P
– G30/G31
Check the type of the supplied gas in the country of installation, and, if needed,
reset the appliance to the other gas type.
Tables 1 and 2 in section
'Technical Specifications'
provide, depending on the
country of installation:
– what gas types may be used to power the appliance;
– nozzles and settings for each gas type that is used.
The number provided in Table 2 for proper nozzles is pressed on nozzles' bodies.
In order to adapt the appliance to the gas type, with which it may be effectively
operated, collect data from Table 2 and perform the following actions:
– exchange main burner's nozzle (UM)
– fit main burner air controller within the distance A
– exchange ignition burner's nozzle (UP)
– perform air adjustment of ignition burner (if needed).
Exchange of Main Burner Nozzle / Primary Air Adjustment
Fig. 1
Fig. 2
1. Remove gas controller.
2. Unscrew front guard (operation panel) and remove it from the appliance.
3. Loosen V bolt (Fig. 2).