background image

7

 

Rev. 1.1 (01.2021)   

                            

 

To log your measurements, 

you can simply click on “Save chart data” to save your measurements. The Data will be 

stored in a .csv file. 

 

 

Since the Sensor used is calibrated for water and you plan on using a different fluid, we added an option to calibrate 
your  system  for  other  fluids  (ideally  water-like  fluids). 

This  “Calibration  Factor”  is  multiplied  with  the  sensor 

measurements displayed in the GUI. To determine what factor your fluid needs, you will need to make a reference 
measurement by e.g. electronic scale and adjust the error with a new calibration factor. 

 

 

 

 

 

 

 

 

 

Summary of Contents for mpSmart-Lowdosing

Page 1: ...1 Rev 1 1 01 2021 Flow Controlled System mpSmart Lowdosing ...

Page 2: ...ht definiert Description of functions Fehler Textmarke nicht definiert Proper use Fehler Textmarke nicht definiert Intended purpose Fehler Textmarke nicht definiert Misuse Fehler Textmarke nicht definiert Staff selection and qualification Fehler Textmarke nicht definiert About this operating manual Fehler Textmarke nicht definiert Getting started with GUI 6 ...

Page 3: ...compliant to the EU Low Voltage Directive 2014 35 EU Description of function The mpSmart Lowdosing have been developed for the transport of liquids The controller has been developed for operating the micropump Bartels Mikrotechnik can assume no liability for damages resulting from the pump media This applies especially for hazardous fluids The pump must be operated with Bartels Mikrotechnik electr...

Page 4: ...ons including vapors is not permitted Staff selection and qualification All work in connection with the installation assembly commissioning decommissioning disassembly operation servicing cleaning and repairing of the pump and the controller must be carried out by qualified suitably trained and instructed personnel Work on electrical components and assemblies must be carried out by personnel with ...

Page 5: ...Flowmeter Sensirion SLF3s 0600F Tubing Tubing connectors Driver Board Software with GUI min Flowrate 5 µl min1 max Flowrate 1000 µl min1 Accuracy 5 Software calibration Water USB port one Input Voltage 5V Operating temperature 5 C bis 45 C Materila in Contact with Fluid PPSU silicon PP PPS stainless steel Tygon epoxy based adhesive Lifetime 5000 h Self priming yes Dimensions 9 5 cm x 9 5 cm x 3 5 ...

Page 6: ...r PC Laptop Starting the Evaluation Software After installing the included software execute the mpSmart Lowdosing exe to start it up The Connection Manager can be found in the top left corner Make sure the USB cable is plugged in and the device is recognized When selected click on Connect to start the communication between the program and the driver If the device was not found you might need to in...

Page 7: ...or water and you plan on using a different fluid we added an option to calibrate your system for other fluids ideally water like fluids This Calibration Factor is multiplied with the sensor measurements displayed in the GUI To determine what factor your fluid needs you will need to make a reference measurement by e g electronic scale and adjust the error with a new calibration factor ...

Page 8: ...tmund Germany www bartels mikrotechnik de info bartels mikrotechnik de Tel 49 231 47730 500 Fax 49 231 47730 501 Visit our Website www bartels mikrotechnik de produkte downloads for further information on applications Tutorials and helpful answers to frequently asked questions can be found in our FAQ www bartels mikrotechnik de en faq english or on our YouTube channel https www youtube com user Ba...

Reviews: