DBL Operation 

 

Low Power Indicator 

 The LED labeled POWER lights RED when the battery needs to be replaced. 
 

Using the DBL 

 The process of using the DBL is one simple operation of holding the tool over the sensor 
and pressing the test button down.   When the TEST button is pressed the green TPMS 
light will come on and stay a solid green color until a signal is received from the sensor in 
the wheel, or the cycle time ends.  The DBL will first attempt to activate Ford 06 sensor 
types, followed by the activation of Schrader.  Please be patient while holding the DBL in 
position as read attempts occur for the various sensor types. 
 

Successful Read 

When the test tool reads the sensor correctly the green TPM light will flash and an 
audible sound will be emitted. 
 

Unsuccessful Read 

The sensor in the wheel was not activated if the TPMS light does not flash, no audible 
signal is heard and the TPMS light then turns off. 

Summary of Contents for DBL TPMS

Page 1: ...DBL TPMS Hand Held Tool ...

Page 2: ...pply 3 DBL Operation 4 Low Power Indicator 4 Using the DBL 4 Successful Read 4 Unsuccessful Read 4 Proper Positioning 5 Ford model year 06 banded sensors 5 Schrader valve stem sensors 5 Additional Information 6 Environmental 6 DBL Technical Brief 6 ...

Page 3: ... harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interface in which case the user will be required to correct the interface at there own expense This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accep...

Page 4: ...l is received from the sensor in the wheel or the cycle time ends The DBL will first attempt to activate Ford 06 sensor types followed by the activation of Schrader Please be patient while holding the DBL in position as read attempts occur for the various sensor types Successful Read When the test tool reads the sensor correctly the green TPM light will flash and an audible sound will be emitted U...

Page 5: ...t be placed directly over the sensor as shown below which 180 degrees from the valve stem Picture 1 Ford model year 06 Banded 1 Schrader valve stem sensors To read the Schrader 315MHz and 433MHz sensors the DBL must be placed over the sensor as shown below which is connected the valve stem Picture 2 Schrader 1 ...

Page 6: ... C Storage Temperature xx degrees to xxx degrees F xx degrees to xxx degrees C Humidity xx to xx non condensing Shock xx K G at xx degrees F xx degrees C DBL Technical Brief Processor Ram Flash programmable memory LED spec Loud Sounder Enclosure Constructed from _____________ injection molded polypropylene alloy ...

Reviews: