Explosion protection and
approvals
Industry Tablet PC 10.1"
Agile X IS
Type 17-A1B*-****/********
EN 10/43
Subject to technical changes.
05/2017
3.
Explosion protection and approvals
ATEX
ATEX Zone 0
Typ:
17-A1B5-****/********
17-A1B6-****/********
II 1 G Ex ia op is IIC T4 Ga
-20 °C ≤ Ta ≤ +50 °C
ATEX Zone 1
Typ:
17-A1B3-****/********
17-A1B4-****/********
II 2 G Ex ia op is IIC T4 Gb
-20 °C ≤ Ta ≤ +50 °C
Test certificate
DEMKO 16 ATEX 1803
Standards
EN 60079-0:2012 + A11: 2013
EN 60079-11: 2012
EN 60079-28: 2015
Guidelines
ATEX 2014/34/EU
EMV 2014/30/EU
R&TTE 1999/5/EC
RoHS 2011/65/EU
IECEx
IECEx Zone 0
Typ:
17-A1B5-****/********
17-A1B6-****/********
Ex ia IIC op is T4 Ga
-20 °C ≤ Ta ≤ +50 °C
IECEx Zone 1
Typ:
17-A1B3-****/********
17-A1B4-****/********
Ex ia IIC op is T4 Gb
-20 °C ≤ Ta ≤ +50 °C
Test certificate
IECEx UL 16.0160
Standards
IEC 60079-0: 2011
IEC 60079-11: 2011
IEC 60079-28: 2014
Guidelines
ATEX 2014/34/EU
EMV 2014/30/EU
R&TTE 1999/5/EC
RoHS 2011/65/EU
UL Class I, Division 1 and Class I Zone 0 / 1
UL Class I
Division 1
Typ:
17-A1B1-****/********
17-A1B4-****/********
17-A1B6-****/********
Class I, Division 1,
Groups A, B, C and D
UL Class I
Zone 0
Typ:
17-A1B6-****/********
Class I, Division 1, Groups A, B, C and D
Class I, Zone 0, AEx ia IIC T4 Ga
-20 °C ≤ Ta ≤ +50 °C
UL Class I
Zone 1
Typ:
17-A1B4-****/********
Class I, Division 1, Groups A, B, C and D
Class I, Zone 1, AEx ia IIC T4 Gb
-20 °C ≤ Ta ≤ +50 °C
Test certificate for USA and Canada
IECEx UL 16.0160
Standards
UL 913: 8th Edition UL 60079-0: 6th Edition
UL 60079-11: 6th Edition
CAN/CSA C22.2 No. 157-92
CAN/CSA C22.2 No. 6079-0:11
CAN/CSA C22.2 No. 6079-11:11
3.1
Applicable standards
See the chapter entitled "EU Certificate of Conformity"