background image

 

SENS (2 symbols). The level of SENS is on 6 .

Setting the Operation Mode

 

Press MODE touch-pad to switch in 3 operation modes with sequence 

 

as (DISC—ALL METAL—NOTCH—DISC), and select one mode.

 

Disc Mode

 

Used for target discrimination. Press MODE, enter DISC mode (DISC 

 

symbol lights). Press SET to convert from SENS to DISC/NOTCH, then 

 

press and hold “+” to increase the metal icons on LCD (also named the 

 

range of discrimination), press and hold “-” to decrease the range of 

 

discrimination. The metal icons are displayed on top of the LCD from left 

 

to right; Nails and Foil, .05¢ coin, Pull Tab, S-caps, .01¢ coin and 

 

0.25¢ coin.

 

All Metal Mode

 

Used for detecting any type of metal. Press MODE to get ALL METAL 

 

mode. LCD displays ALL METAL at the left lower part of the screen. The 

 

discrimination adjustment is not available in this mode. 

 

Begin with the GND BAL knob set in position of P Region, press the 

 

GND TRAC and release to stabilize the unit. It’s recommended the GND 

 

TRAC to be pressed 2-3 times every time you enter the ALL METAL 

 

mode. The unit is operating in non-motion detecting in ALL 

 

METAL mode.

 

Anytime the GND BAL adjusted, the GND TRAC must be pressed 

 afterwards.

 

The detector will sound and the ellipse icons will display in the middle of 

 

LCD screen when detecting a metal object. The ellipse icons here are 

 

just reference levels indicating the estimated depth of the metal 

 

object or the signal strength.

 

Notch Mode

 

To ignore the metal type you do not want. Press MODE to enter NOTCH 

 

mode (NOTCH symbol lights). Press SET to light the DISC/NOTCH 

 

symbol. Press “+”, the target indication arrow will start to blink at 

 

this time. Press ACC/REJ to accept or reject the certain metal type, the 

 

metal icon will light or extinguish to indicate if this type of metal is 

 

selected or rejected. Go on pressing “+”, the blinking arrow will move to 

 

right side (the next metal icon). By pressing “-” , the blinking arrow will 

 

move to the left side (a new metal icon). Repeat above steps to select 

 

or notch the items until you reach the desired setting.

 

Sens Adjustment in Disc & Notch Mode

 

Press SET until SENS symbol at the left upper part of the screen lights. 

 

Press “+” or “-” to increase  or decrease the sensitivity. Be careful to not 

 

set SENS too high or it will lead to the wrong readings or false signals. 

 

To reach the max detection depth, always set SENS as high 

 

as possible. 

Ground Balance
It is used to offset the effects of any minerals present in the soil or to balance the 
effects of saltwater in ALL METAL mode. 

 

1. Begin with the GND BAL adjusted to P Region and lift the search-coil 

 

    about waist high in the air. Press GND TRAC several times to let the 

 

   unit stabilize before starting an effective detection.

 

2. Lower the search-coil to about one inch above the ground and lift the 

 

    search- coil again about waist high in the air. If a tone is not emitted, it 

 

    means the preset position is the proper ground balance for that  

 

    area. If a tone is being emitted, readjust the GND BAL.

 

3. Lift the search coil in the air, turn the GND BAL counterclockwise 

 

    slightly. Press GND TRAC several times. Then repeat step 2. If the 

 

    unit still emits tone, repeat the procedure until the unit does not 

                  emit tone. 

 Note
 

1. Always be careful that there’s no metal on top of or under the ground 

 

   where you conduct ground balancing.

 

2. When adjusting GND BAL counterclockwise, be careful to turn it in 

 

    small increments to ensure that you can achieve the optimum state 

 

    for operation. If you over-rotate the knob counterclockwise, you can 

 

    rotate it back clockwise in the same ground balancing procedure until 

 

    a tone is emitted and then cut it back counterclockwise slightly until 

 

    the tone is no longer emitted.

 

3. Anytime the GND BAL control is adjusted, the GND TRAC touch pad

 

    must be pressed afterwards.

8

www.barska.com

9

www.barska.com

Summary of Contents for BE11922

Page 1: ...f metal target operation models and low battery indication Three Tone Audio Distinctive tones for different types of metal Two operation modes All metal and rejects most junk metals 8 5 Inch Waterproof Search Coil Allowing you to search in shallow water Headphone Jack For private listening www barska com Sharp Edition Metal Detector BC228 9 13 ...

Page 2: ... holes and tighten the knob 2 Press the spring clips on the upper end of the lower stem and slid the lower stem into the upper stem Adjust the stem to a length that can let you maintain a comfortable upright posture with your arm relaxed at your side and the search coil level to the ground 1 2 inches above 3 Wind the coil cable around the stem leave enough slack in the cable Insert the coil plug i...

Page 3: ...phones you can extend the life of the batteries Listening Safely To protect your hearing follow these guidelines when using headphones DO NOT wear headphones while operating your detector near high traffic areas Pay attention to traffic safety After you begin listening adjust the volume to a comfortable level Do not listen at extremely high volume levels Extended high volume listening can lead to ...

Page 4: ... built in audio identification system sounds a unique audio tone for each of three categories of metal This makes it easier to identify the metal being detected Tone Detects Low Tone Foil nails bottle caps and or nickels Medium Tone Pull tabs zinc and or copper items High Tone Brass and or silver items Note When you set the detector to DISC or NOTCH mode the detector sounds a medium or high tone w...

Page 5: ...g the blinking arrow will move to right side the next metal icon By pressing the blinking arrow will move to the left side a new metal icon Repeat above steps to select or notch the items until you reach the desired setting Sens Adjustment in Disc Notch Mode Press SET until SENS symbol at the left upper part of the screen lights Press or to increase or decrease the sensitivity Be careful to not se...

Page 6: ...d ring or a coin on the ground 4 Hold the search coil level to the ground about 1 2 inches above the surface slowly move the search coil over the area where you placed the sample sweeping the search coil in a side to side motion Note If you are using valuable metal such as gold to test the detector mark the area where you place the item to help you find it later Do not place it in tall grass or we...

Page 7: ...cting may be restricted by some factors If you detect patiently and correctly and practice more times you ll get satisfactory result CARE AND MAINTENANCE Your metal detector is an example of superior design and craftsmanship The following suggestions will help you care for your metal detector so you can enjoy it for years Handle the detector gently and carefully Dropping it can damage circuit boar...

Page 8: ...l 1 888 666 6769 for Return Merchandise Number RMA before any returns NOTE All merchandise received without a valid RMA will be returned to shipper at his her own expense Please include all of the following when returning WINBEST by BARSKA products for service and or replacement 1 Please write your complete details Name Address Telephone E mail address RMA etc 2 Purchase receipt or Proof of Purcha...

Reviews: