RDG603A73 - Issue 3
Page 41 of 96
found that improvements in fuel consumption and start ability are an added benefit of using
this product. Diesel fuel additive is available from your Shire dealer in a handy 500ml
container, Part Number RDG80210219.
7. Exhaust Back Pressure (Work Boat with dry exhaust)
•
The engine exhaust outlet must b
e at least 300mm (12”) above the outside seawater
level of the hull. If not an exhaust high rise kit and/or lock box/swan neck must be used
to prevent sea water flowing back up the exhaust and causing engine damage.
The back pressure falls within the manufacturers recommended range when using the
optional exhaust system (see
18. Exhaust System
from
Section 5
– Installation
) with the
engine.
8. Single Shift Control Lever Side Mount Operation - Optional (RDG9210055)
To engage forward or reverse gear:
•
Lift the safety latch under the handle before shifting.
To rev the engine in neutral:
•
Pull the lever out sideways from the main body.
•
Lift the safety latch under the handle then shift
•
Move shift lever backwards or forwards to increase engine speed.