IP33 – Mezzanine Gate   ©  Copyright 2016   

www.barriergroup.com.au

MEZZANINE GATE

 Installation Procedure

Optional U-Bars

When side in-fills are

required, optional surface

mount U-Bars are available

in a range of standard size

UBD100SM-G,

UBD150SM-G,

UBD200SM-G

Optional Reinforment Plate

When mounting posts on timber 

or unsupported floors, the optional 

reinforment plate provides 

additional support to the post. 

WARNING

The gate will not provide optimum performance unless it is installed correctly. For 

satisfactory gate operation please follow the instructions carefully. 

NOTE:

 No guarantee will be given or responsibility accepted by the manufacturers if the gate 

is not installed as instructed. Barrier Group 

do not

 warrant the work of 3rd party contractors. 

BEFORE YOU START

1. The installer must ensure the desired mounting point for the gate is level, plumb and rigid. 

2. Use fixings appropriate to the material into which they are being fixed (not included).  

3. Check all parts are included. Contact Barrier Group immediately if you are missing a piece.

AFTER INSTALLATION CARE 

Barrier Group recommends that you check the operation of your gate at least every six 
months (more regularly in extreme environments or frequent use). It is natural for spring 
assistance unit to lose tension over time. Adjustment may be required.

Important information.

Read carefully. 

Keep this information for further reference. 

Summary of Contents for MEZZANINE GATE

Page 1: ...MEZZANINE GATE Installation Procedure IP33 Mezzanine Gate Copyright 2016 www barriergroup com au Optional Double Rail U Bars ...

Page 2: ...Procedure 1290 DRILL THROUGH to suit M6 1208 1118 x 1 x 1 x 1 x 1 x 2 x 1 x 2 x 4 x 2 x 1 M8 Nylock Nut M8 x 35 Hex bolt M8 Washer M12 CONTENTS x 1 x 1 IP33 Mezzanine Gate Copyright 2016 www barriergroup com au D H G A B C E F I J ...

Page 3: ...pyright 2016 www barriergroup com au Gap should not exceed 100mm x 4 M12 Note Ensure to choose appropriate fixing to suit flooring STEP 1 G E 200 2002 1602 200 119 200 1508 200 200 1259 200 200 1603 200 130 DROP Footprint layout as shown is for standard MZ1500 A ...

Page 4: ...MEZZANINE GATE Installation Procedure IP33 Mezzanine Gate Copyright 2016 www barriergroup com au STEP 2 x 6 M12 x 1 x 1 x 1 STEP 2 G A B C ...

Page 5: ... connector I is a slip fit onto square shaft on H post remove any galvanising build up at both end from ins s ide I prior a to ssembly CAUTION DO NOT force I onto square shaft on H post as it could casue damage to aluminium bushes IP33 Mezzanine Gate Copyright 2016 www barriergroup com au STEP 3 STEP 4 I H G G A B C E E A B C ...

Page 6: ...MEZZANINE GATE Installation Procedure IP33 Mezzanine Gate Copyright 2016 www barriergroup com au STEP 5 R ECOMMENDE 0 0 4 D D H STEP 5 G A B C E ...

Page 7: ...MEZZANINE GATE Installation Procedure IP33 Mezzanine Gate Copyright 2016 www barriergroup com au STEP 6 M12 CAUTION message must be applied on rail prior operation STEP 6 F H G E ...

Page 8: ...n or responsibility accepted by the manufacturers if the gate is not installed as instructed Barrier Group do not warrant the work of 3rd party contractors BEFORE YOU START 1 The installer must ensure the desired mounting point for the gate is level plumb and rigid 2 Use fixings appropriate to the material into which they are being fixed not included 3 Check all parts are included Contact Barrier ...