5.
Keep hands, hair, clothing and tools away from all moving parts
when operating or
repairing the equipment.
6. Never operate the equipment unless all guards and protective covers are in place.
Do
not
attempt to bypass safety devices to operate the equipment
.
7.
Never use this machine with flammable liquids
or a fire or explosion may result
causing serious injury.
If you encounter operating difficulties please contact the Barrett Customer Service
Department at 1-800-228-6442.
MACHINE SET-UP
WARNING!
Do not attempt to lift the machine by the rotating assembly
!
Doing
so will damage the motor and/or pan. Lift the machine using all four drum access
holes (9" x 7" opening on the lower part of the drum) or the inside lip of the drum head
(with lid open) using a multi-hook chain or sling.
Locate the machine in the desired position. Transfer the bolt hole locations from the base to
the floor. Level the machine by shimming under the base at the anchor bolt holes to insure
full, solid support. On wooden floors, straddle the beams and use through bolts. On concrete
floors, Barrett recommends the use of epoxy-set type anchors to secure the machine to the
floor.
The machine must be absolutely solid with the floor. Do not set in wet cement!
Do not run machine without anchoring or vibration may allow it to move about and
damage the electrical connections.!
WIRING
The wiring of this equipment should be performed by a qualified electrician, and be in
accordance with OSHA Electrical Standards, the National Electrical Code and local codes,
and also, be in accordance with the wiring diagram provided with these instructions. A
control panel, with a disconnect switch, motor starters, transformers, fuses, cycle timer, PLC
and D.C. brake circuit is provided for wall mounting.
The customer must provide service to the panel. Feed lines should be connected to the
panel's disconnect switch.
The full load current is approximately 32 amps. Feed lines
should be number 8 wire or larger
.
Fusing in the panel is per equipment requirements and
should not be altered without first consulting the factory.
The main machine motor, motor cooling blower, if provided, and auxiliary devices are pre-
wired, at the factory, to the machine junction box. Matching numbered terminal strips in the
junction box and control panel must be wired together, via conduit, at installation. High