background image

16

Barnstead|Thermolyne Corporation warrants that if a product manufactured by

Barnstead|Thermolyne and sold by it within the continental United States or Canada
proves to be defective in material or construction, it will provide you, without charge, for a
period of ninety (90) days, the labor, and a period of one (1) year, the parts, necessary to
remedy any such defect. Outside the continental United States and Canada, the warranty
provides, for one (1) year, the parts necessary to remedy any such defect. The warranty
period shall commence either six (6) months following the date the product is sold by
Barnstead|Thermolyne or on the date it is purchased by the original retail consumer,
whichever date occurs first.

All warranty inspections and repairs must be performed by and parts obtained from

an authorized Barnstead|Thermolyne dealer or Barnstead|Thermolyne (at its own
discretion). Heating elements, however, because of their susceptibility to overheating and
contamination, must be returned to our factory, and if, upon inspection, it is concluded that
failure is not due to excessive high temperature or contamination, warranty replacement will
be provided by Barnstead|Thermolyne. The name of the authorized
Barnstead|Thermolyne dealer nearest you may be obtained by calling 1-800-446-6060 or
writing to:

Barnstead|Thermolyne

P.O. Box 797

2555 Kerper Boulevard

Dubuque, IA 52004-0797

USA

FAX: (319) 589-0516

E-MAIL ADDRESS: [email protected]

Barnstead|Thermolyne’s sole obligation with respect to its product shall be to repair

or (at its own discretion) replace the product. Under no circumstances shall it be liable for
incidental or consequential damage.

THE WARRANTY STATED HEREIN IS THE SOLE WARRANTY APPLICABLE TO

Barnstead|Thermolyne PRODUCTS. Barnstead|Thermolyne EXPRESSLY DISCLAIMS
ANY AND ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR USE.

One Year Limited Warranty

9001

ISO

REGISTERED

Barnstead|Thermolyne

2555 Kerper Blvd.
P.O. Box 797
Dubuque, IA  52004-2241
Phone: 319-556-2241  800-553-0039
Fax: 319-589-0516
E-Mail Address: [email protected]

Summary of Contents for 494 Series

Page 1: ...1 Type D0800 Bantam Cartridge Holder OPERATION MANUAL AND PARTS LIST SERIES 494 BARNSTEAD THERMOLYNE CORPORATION 60119 3 12 98 Model Voltage D0800 120 D0805 240...

Page 2: ...trapure Mixed Resin 5 Installation 6 Unpacking 6 Choosing a Site 6 Mounting 6 Plumbing Service Connections 6 Elbow Tubing Assembly 8 Cartridge Installation 9 Operation 10 Purity Meter Operation 10 Mai...

Page 3: ...ughout the manual Warnings To avoid electrical shock always 1 Use a properly grounded electrical outlet of correct voltage and current handling capacity 2 Disconnect from the power supply prior to mai...

Page 4: ...i u q e r l a c i r t c e l E 0 0 8 0 D l e d o M 1 z H 0 6 0 5 V 0 2 1 e s a h p 2 z H 0 6 0 5 V 0 2 1 e s a h p 1 2 5 0 8 0 D 1 z H 0 6 0 5 V 0 4 2 e s a h p 2 z H 0 6 0 5 V 0 4 2 e s a h p 1 2 Note...

Page 5: ...the cartridge is new Ultrapure Mixed Resin This cartridge catalog no D0809 has the capacity to remove 65 grams 750 grains of dissolved ionized impurities as NaCl About 3 4 75 of the capacity is capabl...

Page 6: ...Mounting The Bantam Holder is shipped assembled for bench mounting Four screws are provided for wall mounting if desired Plumbing Service Connections The Bantam Holders are supplied with polypropylen...

Page 7: ...drain on the Bantam Holder to the sink and to make the plumbing service connection between the holder effluent connection at the top of the unit and the point of distribution 4 Thread the 1 8 NPT x 1...

Page 8: ...nd backup ring in the adapter nut and install the nut on the elbow Do not install the o ring at this time 4 Push the tubing through the nut until it bottoms out in the elbow 5 Remove the adapter nut t...

Page 9: ...wn to allow the cartridge to be centered between the top and bottom o ring 3 Turn the lower tightening wheel until the cartridge seats against the top o ring INSTALLATION Note Water purified by the io...

Page 10: ...ing Meter by setting the on off switch to the on position When the purity meter drops below the acceptable minimum purity or when the purity meter needle registers in the 0 05 to 0 025 megohm red rang...

Page 11: ...er needle is aligned with the line indicating the beginning of the meter scale The zero adjustment screw is located on the face of the meter below the scales 3 To calibrate the meter further connect a...

Page 12: ...12 Exploded View...

Page 13: ...x D O 4 1 s s a r b e v l a V 7 V 5 1 1 8 3 5 1 2 V 0 3 2 9 1 0 3 3 r e t e M 8 7 9 5 5 1 r e d l o h e g d i r t r a C 9 6 9 8 5 1 e l p p i N 0 1 2 0 5 5 1 l e e h W g n i n e t h g i T r e w o L 1...

Page 14: ...whom you purchased this unit or can be obtained promptly from the factory When service or replacement parts are needed we ask that you check first with your dealer If the dealer cannot handle your re...

Page 15: ...15...

Page 16: ...ng and contamination must be returned to our factory and if upon inspection it is concluded that failure is not due to excessive high temperature or contamination warranty replacement will be provided...

Reviews: